Analysis of the application of the generalized monod kinetics model to describe the human corneal oxygen-consumption rate during soft contact lens wear.

نویسندگان

  • V Compañ
  • M Aguilella-Arzo
  • L F Del Castillo
  • S I Hernández
  • J M Gonzalez-Meijome
چکیده

This work is an analysis of the application of the generalized Monod kinetics model describing human corneal oxygen consumption during soft contact lens wear to models previously used by Chhabra et al. (J Biomed Mater Res B Appl Biomater, 2009a;90:202-209, Optom Vis Sci 2009b;86:454-466) and Larrea and Büchler (Invest Ophthalmol Vis Sci 2009;50:1076-1080). We use oxygen tension from in vivo estimations provided by Bonanno [Bonanno et al., Invest Ophthalmol Vis Sci 2002;43:371-376, and Bonanno et al 2009]. We consider four hydrogel and six silicone hydrogel lenses. The cornea is considered a single homogeneous layer, with constant oxygen permeability regardless of the type of lens worn. Our calculations yield different values for the maximum oxygen consumption rate Qc,max , whith differents oxygen tensions (high and low pc ) at the cornea-tears interface. Surprisingly, for both models, we observe an increase in oxygen consumption near an oxygen tension of 105 mmHg until a maximum is reached, then decreasing for higher levels of oxygen pressure. That is, when lowering the pressure of oxygen, the parameter Qc,max initially increases depending on the intensity of the change in pressure. Which, it could be related with the variation of the pH. Furthermore, it is also noted that to greater reductions in pressure, this parameter decreases, possibly due to changes in the concentration of glucose related to the anaerobic respiration. The averaged in vivo human corneal oxygen consumption rate of 1.47 × 10-4 cm3 of O2 /cm3 tissue s, with Monod kinetics model, considering all the lenses studied, is smaller than the average oxygen consumption rate value obtained using the Larrea and Büchler model. The impact that these calculations have on the oxygen partial pressure available at different depths in the corneal tissue is presented and discussed, taking into consideration previous models used in this study. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2269-2281, 2017.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion and Monod kinetics model to determine in vivo human corneal oxygen-consumption rate during soft contact lens wear.

PURPOSE We present an analysis of the corneal oxygen consumption Qc from non-linear models, using data of oxygen partial pressure or tension (P(O2) ) obtained from in vivo estimation previously reported by other authors. (1) METHODS: Assuming that the cornea is a single homogeneous layer, the oxygen permeability through the cornea will be the same regardless of the type of lens that is availabl...

متن کامل

امکان استفاده از آنزیم EcoR1 در طبقه بندی سویه های اکانتامبای ایزوله شده از التهاب قرنیه

Acanthamoeba keratitis is increasingly being diagnosed among people who wear thrapeutic and cosmetic contact lenses. The chain of events is thought to begin with contamination of the contact lens storage cases with Acanthamoeba from household or mains water supplies. If bacteria contamination is also present then these amoebas can multiply by ingesting the bacteria as a food source. If the cont...

متن کامل

Corneal and conjunctival sensory function: the impact on ocular surface sensitivity of change from low to high oxygen transmissibility contact lenses.

PURPOSE Deprivation of oxygen to the ocular surface during contact lens wear has been implicated in the alteration of sensory function. This study investigates whether increasing oxygen availability through discontinuation of contact lens wear or transfer into highly oxygen transmissible (high Dk/t) lenses leads to a change in corneal or conjunctival sensitivity. METHODS Twenty-seven long-ter...

متن کامل

Corneal epithelial permeability during extended wear of disposable contact lenses versus daily wear of soft contact lenses.

AIMS The corneal epithelial permeability during extended wear of disposable contact lenses was compared with that during daily wear of soft contact lenses. The study was performed to verify whether the extended wear of disposable contact lenses would result in a higher permeability value than the daily wear of soft contact lenses. A higher permeability makes the cornea more vulnerable for bacte...

متن کامل

Corneal epithelial and aqueous humor acidification during in vivo contact lens wear in rabbits.

PURPOSE Based on contact lens-induced stromal acidification of the cornea, it has been suggested that the corneal epithelial and endothelial cells also become acidotic during contact lens wear. This alleged acidification may have a role in altered cell appearance and metabolism during contact lens wear. This study investigated the effects of anoxia, carbon dioxide retention, and contact lens ga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 105 8  شماره 

صفحات  -

تاریخ انتشار 2017