Selective pressurized liquid extraction of polychlorinated biphenyls in sediment.

نویسندگان

  • Rikard Westbom
  • Sune Sporring
  • Louise Cederberg
  • Lars-Ola Linderoth
  • Erland Björklund
چکیده

A selective pressurized liquid extraction procedure (SPLE) was developed for a fast determination of polychlorinated biphenyls in sediment. The final method was performed at 100 degrees C with heptane/dichloromethane (90:10, v/v) as extraction solvent for 2x5 min. Sulfuric acid impregnated silica was placed downstream of the sample in the extraction cell to remove interfering components. This simultaneous extraction/clean-up was performed in 20 min, with an average congener recovery of 92% compared to a classical 24 h Soxhlet methodology and 2 h of external manual clean-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of polychlorinated biphenyls in soil and sediment by selective pressurized liquid extraction with immunochemical detection.

A selective pressurized liquid extraction (SPLE) method was developed for a streamlined sample preparation/cleanup to determine Aroclors and coplanar polychlorinated biphenyls (PCBs) in soil and sediment. The SPLE was coupled with an enzyme-linked immunosorbent assay (ELISA) for an effective analytical approach for environmental monitoring. Sediment or soil samples were extracted with alumina, ...

متن کامل

Optimization of pressurized liquid extraction (PLE) of dioxin-furans and dioxin-like PCBs from environmental samples.

Pressurized liquid extraction (PLE) applying three extraction cycles, temperature and pressure, improved the efficiency of solvent extraction when compared with the classical Soxhlet extraction. Polychlorinated-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like PCBs (coplanar polychlorinated biphenyls (Co-PCBs)) in two Certified Reference Materials [DX-1 (sediment) and BCR...

متن کامل

Biodegradation of Polychlorinated Biphenyls by and Isolated from Contaminated Soil

Polychlorinated biphenyls (PCBs) cause many significant ecological problems because of their low degradability, high harmfulness, and solid bioaccumulation.Two bacterial strains were isolated from soil that had been polluted with electrical transformer liquid for more than 40 years. The isolates were distinguished as Lysinibacillus macrolides DSM54Tand Bacillus firmus NBRC1530...

متن کامل

Solvent selection for pressurized liquid extraction of polymeric sorbents used in air sampling.

Pressurized liquid extraction (PLE) was evaluated as a method for extracting semivolatile organic compounds (SOCs) from air sampling media, including quartz fiber filter (QFF), polyurethane foam (PUF), and a polystyrene divinyl benzene copolymer (XAD-2). Hansen solubility parameter plots were used to aid in the PLE solvent selection in order to both reduce coextraction of polyurethane and save ...

متن کامل

Evaluation of supercritical fluid extraction for isotope dilution gas chromatography-mass spectrometric quantification of polychlorinated biphenyls in sediment.

Supercritical fluid extraction (SFE) has been evaluated as an extraction technique for the isotope-dilution quantification of polychlorinated biphenyls (PCBs) in a sediment sample. A high-resolution mass-spectrometric system equipped with a gas chromatograph was employed for the determination of seven target PCB congeners. The effect of the operation parameters on the SFE efficiency was investi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2008