The accuracy of Doppler ultrasound measurement of pressure gradients across irregular, dual, and tunnellike obstructions to blood flow.
نویسندگان
چکیده
The accuracy of Doppler-estimated pressure gradients in the setting of irregular, multiple, and tunnellike stenoses was investigated. An in vitro model of the left ventricular outflow tract was designed to allow pulsatile flow of red cells in saline across valve orifices from 0.01 to 2.5 cm2. Simultaneous pressure gradients were estimated by both Doppler and direct-pressure manometer techniques. Gradients obtained by the two methods correlated well for valve areas in the range of clinical stenoses at pressure gradients of 10 to 150 mm Hg (r = .97 to .99). Model valves were constructed with a large orifice (0.75 to 1.25 cm2) placed beside a small orifice (0.02 to 0.25 cm2) in the same outflow tract. A distinct jet was recorded when the Doppler transducer was aligned with each orifice. Doppler-estimated gradients for each pair of large and small orifices were identical and correlated well with those measured by manometer (r = .97 to .99). Irregularly shaped orifices also provided good correlation between the two methods (r = .98 to .99). Pulsatile flow was generated through long tunnellike obstructions with cross-sectional areas varying from 0.06 to 1.25 cm2. Tunnel length varied from 0.1 to 4 cm. Tunnel areas above 0.25 cm2 gave good Doppler-to-manometer correspondence at all tunnel lengths. Doppler underestimated manometer-determined values in the 0.25 cm2 tunnel by 8% at 3 cm and by 15% at 4 cm. In the 0.06 cm2 tunnel, Doppler underestimated manometer gradients by 12%, 15%, 32%, and 42% at lengths of 1, 2, 3, and 4 cm, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملبرآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید
Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...
متن کاملDOPPLER ECHOCARDIOGRAPHY Continuous - wave Doppler velocities and gradients across fixed tunnel obstructions : studies in vitro and in vivo
The simplified Bernoulli relationship appears to be quite accurate for predicting gradients across discrete valvular obstructions. Controversy exists about how accurately it predicts the severity of disease in longer segment obstructions. In this study we constructed a pulsatile model of subvalvular pulmonary stensosis in vitro to study nine custom-made subvalvular tunnels 2, 4, and 7 mm in len...
متن کاملTissue blood flow measurement by laser Doppler technique
Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...
متن کاملContinuous-wave Doppler velocities and gradients across fixed tunnel obstructions: studies in vitro and in vivo.
The simplified Bernoulli relationship appears to be quite accurate for predicting gradients across discrete valvular obstructions. Controversy exists about how accurately it predicts the severity of disease in longer segment obstructions. In this study we constructed a pulsatile model of subvalvular pulmonary stensosis in vitro to study nine custom-made subvalvular tunnels 2, 4, and 7 mm in len...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 72 3 شماره
صفحات -
تاریخ انتشار 1985