Detection of aortic porcine valve dysfunction by maximum entropy spectral analysis.

نویسندگان

  • R A Foale
  • T H Joo
  • J H McClellan
  • R W Metzinger
  • G L Grant
  • G S Myers
  • R S Lees
چکیده

A high-resolution method of spectral analysis, of the class generally called "maximum entropy method," was used in a study of aortic porcine valve closing sounds in 37 patients (ages 19 to 76). Spectra from 27 normal xenografts, implanted from 2 weeks to 61 months previously, were characterized by a dominant frequency peak, F1, at 89 +/- 15 Hz (mean +/- SD), with a lower amplitude peak, F2, at 154 +/- 25 Hz. Eight of nine patients with aortic porcine valve dysfunction were proved surgically to have leaflet degeneration or infection and had either F1 (139 +/- 54 Hz) and/or F2 (195 +/- 74 Hz) significantly higher than normal (p less than .001). In two patients with paravalvar leak but no leaflet abnormality, F1 and F2 were in the normal range. Estimation of F1 and F2 was highly reproducible and was unaffected by duration of implant up to 5 years. Spectral analysis of aortic porcine valve closing sounds by the maximum entropy method may be useful for detection of intrinsic xenograft dysfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DIAGNOSTIC METHODS NONINVASIVE GRAPHIC METHODS Detection of aortic porcine valve dysfunction by maximum entropy spectral analysis

A high-resolution method of spectral analysis, of the class generally called "maximum entropy method," was used in a study of aortic porcine valve closing sounds in 37 patients (ages 19 to 76). Spectra from 27 normal xenografts, implanted from 2 weeks to 61 months previously, were characterized by a dominant frequency peak, Fl, at 89 + 15 Hz (mean + SD), with a lower amplitude peak, F2, at 154 ...

متن کامل

Transcatheter CoreValve valve-in-valve implantation in a stentless porcine aortic valve for severe aortic regurgitation

KEY CLINICAL MESSAGE We describe the first valve-in-valve Corevalve transcatheter aortic valve replacement in the St. Jude Toronto stentless porcine aortic valve in the United States, which enabled this 59-year-old patient with a history of bacterial endocarditis and aortic regurgitation to avoid heart transplant with complete resolution of his severe left ventricular dysfunction.

متن کامل

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

A nonlinear anisotropic model for porcine aortic heart valves.

The anisotropic property of porcine aortic valve leaflet has potentially significant effects on its mechanical behaviour and the failure mechanisms. However, due to its complex nature, testing and modelling the anisotropic porcine aortic valves remains a continuing challenge to date. This study has developed a nonlinear anisotropic finite element model for porcine heart valves. The model is bas...

متن کامل

Echocardiographic changes in the thickness of porcine valves with time.

To assess the ability of M-mode echocardiography to detect the incidence and frequency of porcine xenograft valve thickening, echocardiograms were obtained in 147 mitral and aortic porcine xenograft valves implanted in 131 patients. The patients were divided into an early group in whom the echocardiograms were performed within two months of valve replacement, and intermediate group studied two ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 68 1  شماره 

صفحات  -

تاریخ انتشار 1983