Programmed inappropriate ICD ventricular defibrillation for cardioversion of persistent atrial fibrillation
نویسندگان
چکیده
In this report we briefly describe a patient with a dual chamber implantable cardioverter defibrillator in the context of severe ischemic cardiomyopathy who developed persistent atrial fibrillation. After appropriate anticoagulation and under mild sedation the patient was successfully cardioverted to sinus rhythm after a programmed ventricular synchronized defibrillation using his defibrillator. Programmed internal cardioversion of persistent atrial fibrillation in patients who have an implantable cardioverter defibillator without atrial defibrillation capabilities could be an effective and safe therapeutic option. Unlike external electrical cardioversion, this strategy does not interfere with the implantable cardioverter defibrillator, is more effective, and obviates the need of general anesthesia. This strategy should be further evaluated in clinical trials.
منابع مشابه
Favorable effects of flecainide in transvenous internal cardioversion of atrial fibrillation.
OBJECTIVES The aim of the study was to evaluate the effects of intravenous (IV) flecainide on defibrillation energy requirements in patients treated with low-energy internal atrial cardioversion. BACKGROUND Internal cardioversion of atrial fibrillation is becoming a more widely accepted therapy for acute episode termination and for implantable atrial defibrillators. METHODS Twenty-four pati...
متن کاملInternal cardioversion of persistent atrial fibrillation in implantable cardioverter defibrillator patients: the juice is not worth the squeeze
Atrial fibrillation (AF) is the most common arrhythmia and its prevalence and incidence increase with age, but also with cardiovascular morbidity, such as hypertension, diabetes, vascular and valvular disease and heart failure. Indeed, in patients with implantable cardioverter defibrillators (ICD), who usually have one or more of these predisposing factors, a history of AF was present in 33 % [...
متن کاملLow efficacy of cardioversion of persistent atrial fibrillation with the implantable cardioverter-defibrillator
AIMS Atrial fibrillation (AF) and heart failure are conditions that often coexist. Consequently, many patients with an implantable cardioverter-defibrillator (ICD) present with AF. We evaluated the effectiveness of internal cardioversion of AF in patients with an ICD. METHODS Retrospectively, we included 27 consecutive ICD patients with persistent AF who underwent internal cardioversion using...
متن کاملDefibrillation and Cardioversion
Defibrillation is the treatment for immediately life-threatening arrhythmias with which the patient does not have a pulse, ie ventricular fibrillation (VF) or pulseless ventricular tachycardia (VT). Cardioversion is any process that aims to convert an arrhythmia back to sinus rhythm. Electrical cardioversion is used when the patient has a pulse but is either unstable, or chemical cardioversion ...
متن کاملDefibrillation and Cardioversion
Defibrillation is the treatment for immediately life-threatening arrhythmias with which the patient does not have a pulse, ie ventricular fibrillation (VF) or pulseless ventricular tachycardia (VT). Cardioversion is any process that aims to convert an arrhythmia back to sinus rhythm. Electrical cardioversion is used when the patient has a pulse but is either unstable, or chemical cardioversion ...