A novel device for resonance frequency assessment of one-piece implants.

نویسندگان

  • Eran Gabay
  • Omer Cohen
  • Eli E Machtei
چکیده

PURPOSE Immediate loading and/or restoration of dental implants requires the assessment of implant stability, which is best performed by resonance frequency analysis (RFA) prior to loading. One-piece dental implants are usually used for immediate loading, but there is currently no available reliable method to assess the primary stability of one-piece dental implants. Therefore, this study sought to validate a novel device designed for RFA measurements of one-piece implants. MATERIAL AND METHODS Thirty (3.75 x 13 mm) internal-hex implants (Seven, MIS) were divided into two groups; 15 were placed in an acrylic glass block and 15 were placed in fresh porcine jawbone using 30 N/cm2 of insertion torque. Implant stability quotient (ISQ) values were measured using the Osstell Mentor device; then, a new external fixation device was attached to the implant abutment with a 10-mm arm extending from the implant to an internal-hex ring at its proximal end. ISQ values were measured at the implant's internal hex and at the internal hex of the device, and the damping ratio was calculated. The measurements were repeated with 15 (3 x 13 mm) one-piece implants (UNO, MIS) attached to the same device. RESULTS The damping ratio between the implant and the proximal device was 23.6% ± 4% in acrylic glass (50.1 ± 1.7 ISQ and 38.2 ± 1.8 ISQ, respectively) and 23.1% ± 3% in porcine bone (74.9 ± 2.8 ISQ and 57.5 ± 0.5 ISQ, respectively). ISQ values determined by the device on one-piece and two-piece implants were similar (57.4 ± 0.9 and 57.5 ± 0.5, respectively). CONCLUSION With the present validation of this external fixation device for the measurements of implant stability using RFA, it is now possible to measure primary stability of any one-piece implant system, obviating the need for custom-made Osstell adaptors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one...

متن کامل

A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading.

PURPOSE In this study, standard Brånemark System implants and Brånemark TiUnite implants were evaluated regarding primary stability and placement torque. The correlation between placement torque and primary stability as well as the influence of implant design on placement torque and primary stability were examined. MATERIALS AND METHODS Twelve patients who presented bilateral loss of either m...

متن کامل

Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites

Background and aim:  Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...

متن کامل

ON STANDARD CALIBRATION OF ISQ TRANSDUCER PEGS. Prerequisites for accurate and comparable RFA measurements

The resonance frequency analysis (RFA) technique is widely used for stability assessments of dental implants. The technique makes use of a transducer peg, which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the peg. The underlying RF in Hz is then translated to an Implant Stability Quotient (ISQ) on a scal...

متن کامل

Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws

Several histologic studies regarding peri-implant soft tissues and biological width around dental implants have been done in animals. However, these findings in human peri-implant soft tissues are very scarce. Therefore, the aim of this case series was to compare the biological width around unloaded one- and two-piece implants retrieved from human jaws. Eight partially edentulous patients recei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2012