Calculation of physiologic dead space: comparison of ventilator volumetric capnography to measurements by metabolic analyzer and volumetric CO2 monitor.

نویسندگان

  • Mark S Siobal
  • Hannah Ong
  • Josephine Valdes
  • Julin Tang
چکیده

BACKGROUND Calculation of physiologic dead space (dead space divided by tidal volume [VD/VT]) using the Enghoff modification of the Bohr equation requires measurement of the partial pressure of mean expired CO2 (PĒCO2) by exhaled gas collection and analysis, use of a metabolic analyzer, or use of a volumetric CO2 monitor. The Dräger XL ventilator is equipped with integrated volumetric CO2 monitoring and calculates minute CO2 production (VCO2). We calculated PĒCO2 and VD/VT from ventilator derived volumetric CO2 measurements of VCO2 and compared them to metabolic analyzer and volumetric CO2 monitor measurements. METHODS A total of 67 measurements in 36 subjects recovering from acute lung injury or ARDS were compared. Thirty-one ventilator derived measurements were compared to measurements using 3 different metabolic analyzers, and 36 ventilator derived measurements were compared to measurements from a volumetric CO2 monitor. RESULTS There was a strong agreement between ventilator derived measurements and metabolic analyzer or volumetric CO2 monitor measurements of PĒCO2 and VD/VT. The correlations, bias, and precision between the ventilator and metabolic analyzer measurements for PĒCO2 were r = 0.97, r(2) = 0.93 (P < .001), bias -1.04 mm Hg, and precision ± 1.47 mm Hg. For VD/VT the correlations were r = 0.95 and r(2) = 0.91 (P < .001), and the bias and precision were 0.02 ± 0.04. The correlations between the ventilator and the volumetric CO2 monitor for PĒCO2 were r = 0.96 and r(2) = 0.92 (P < .001), and the bias and precision were -0.19 ± 1.58 mm Hg. The correlations between the ventilator and the volumetric CO2 monitor for VD/VT were r = 0.97 and r(2) = 0.95 (P < .001), and the bias and precision were 0.01 ± 0.03. CONCLUSIONS PĒCO2, and therefore VD/VT, can be accurately calculated directly from the Dräger XL ventilator volumetric capnography measurements without use of a metabolic analyzer or volumetric CO2 monitor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physiologic dead space assessment: field of dreams or clinical paradigm?

In this issue of RESPIRATORY CARE, Siobal and colleagues report on the correlation, precision, and bias of calculated physiologic dead space, determined using the volumetric capnography module available in the Dräger XL ventilator, compared to other methods (metabolic analyzer and volumetric CO2 monitor).1 It is important to note that the investigators choose comparative technologies that refle...

متن کامل

Accuracy of physiologic dead space measurements in patients with acute respiratory distress syndrome using volumetric capnography: comparison with the metabolic monitor method.

BACKGROUND Volumetric capnography is an alternative method of measuring expired carbon dioxide partial pressure (P(eCO2)) and physiologic dead-space-to-tidal-volume ratio (V(D)/V(T)) during mechanical ventilation. In this method, P(eCO2) is measured at the Y-adapter of the ventilator circuit, thus eliminating the effects of compression volume contamination and the need to apply a correction fac...

متن کامل

Volumetric capnography in acute respiratory distress syndrome: is the era of day-to-day monitoring finally here?

Acute lung injury (ALI) and the acute respiratory distress syndrome (ARDS) affect 4.5–7.1% of the patients admitted to the intensive care unit with acute respiratory failure.1,2 In our population, we found that ARDS affects 15.3 per 100,000 persons per year.3 Although the reported mortality of patients with ALI and ARDS has improved, it remains high among the causes of death in the intensive ca...

متن کامل

Can Transcutaneous CO2 Tension Be Used to Calculate Ventilatory Dead Space? A Pilot Study

Dead space fraction (V d/V t) measurement performed using volumetric capnography requires arterial blood gas (ABG) sampling to estimate the partial pressure of carbon dioxide (PaCO2). In recent years, transcutaneous capnography (PtcCO2) has emerged as a noninvasive method of estimating PaCO2. We hypothesized that PtcCO2 can be used as a substitute for PaCO2 in the calculation of V d/V t. In thi...

متن کامل

Monitoring Dead Space in Mechanically Ventilated Children: Volumetric Capnography Versus Time-Based Capnography.

BACKGROUND Volumetric capnography dead-space measurements (physiologic dead-space-to-tidal-volume ratio [VD/VT] and alveolar VD/VT) are considered more accurate than the more readily available time-based capnography dead-space measurement (end-tidal alveolar dead-space fraction [AVDSF]). We sought to investigate the correlation between volumetric capnography and time-based capnography dead-spac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 7  شماره 

صفحات  -

تاریخ انتشار 2013