Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis

نویسندگان

  • Eun Mi Yang
  • Eujin Park
  • Yo Han Ahn
  • Hyun Jin Choi
  • Hee Gyung Kang
  • Hae Il Cheong
  • Il Soo Ha
چکیده

Adequate fluid management is an important therapeutic goal of dialysis. Recently, bioelectrical impedance methods have been used to determine body fluid status, but pediatric reports are rare. To determine the accuracy of bioelectrical impedance methods in the assessment of body fluid statusof children undergoing hemodialysis (HD), 12 children on HD were studied. A multi-frequency bioimpedance analysis device (Inbody S10) and bioimpedance spectroscopy device (BCM) were used to evaluate fluid status. Fluid removal during a HD session (assessed as body-weight change, ΔBWt) was compared with the difference in total body water determined by each device (measured fluid difference, ΔMF), which showed strong correlation using either method (Pearson's coefficient, r = 0.772 with Inbody S10 vs. 0.799 with BCM). Bioimpedance measurement indicated fluid overload (FO; ΔHS greater than 7%) in 34.8% with Inbody S10 and 56.5% with BCM, and only about 60% of children with FO by bioimpedance methods showed clinical symptoms such as hypertension and edema. In some patients with larger weight gain Inbody S10-assessed overhydration (OH) was much smaller than BCM-assessed OH, suggesting that BCM is more relevant in estimating fluid accumulation amount than Inbody S10. To our knowledge, this is the first report on the use of body composition monitors to assess fluid status in Korean children receiving HD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluid status evaluation by inferior vena cava diameter and bioimpedance spectroscopy in pediatric chronic hemodialysis

BACKGROUND Evaluation of patient's dry weight remains challenging in chronic hemodialysis (HD) especially in children. Inferior Vena Cava (IVC) measurement was reported useful to assess fluid overload both in adults and children. METHODS We performed a monocentric prospective study to evaluate the relation between predialytic IVC diameter measurements and hydration status evaluated by physici...

متن کامل

Assessment of Fluid Shifts of Body Compartments using Both Bioimpedance Analysis and Blood Volume Monitoring

Fluid shifts are commonplace in chronic hemodialysis patients during the intra- and interdialytic periods. In this study, we evaluated fluid shifts of body compartments using both bioimpedance spectroscopy and blood volume monitoring from the start to the end of hemodialysis. 24 stable hemodialysis patients were included on the study. Relative change of blood volume was progressively reduced fr...

متن کامل

Estimation of body composition and normal fluid status using a calf bioimpedance technique.

UNLABELLED The aims of this study in hemodialysis (HD) patients were: 1. To evaluate the relationship of calf bioimpedance with total body composition and fluid status as measured by gold standard methods. 2. To investigate the ability of calf normalized resistivity (CNR) to predict the normal fluid status (dry weight: DW) in a prospective study. In the body composition study (n = 41), fluid st...

متن کامل

Time to improve fluid management in hemodialysis: should we abandon clinical assessment and routinely use bioimpedance?

Underestimation of the dry weight of hemodialysis patients can result in unwelcome symptoms and intradialytic hypotension, which may be associated with adverse outcomes (1,2). Similarly, overestimation of dryweight can lead to chronic volume overload,which increases cardiovascular morbidity and mortality (3). In reality, there are problems in detecting both hypovolemia and hypervolemia (4). Not...

متن کامل

Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis.

BACKGROUND The accurate assessment of body fluid volume is important in many clinical situations. Hannan et al. proposed a single-frequency bioimpedance equation (HE) to calculate extracellular water (ECW) and total body water (TBW). There are two equations based on the bioimpedance spectroscopy (BIS) method for the evaluation of body fluid volume: Xitron equations (XE) and body composition spe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2017