SU-E-I-52: Noise Level and Contrast Dependent Behavior of MTF in Iterative Reconstruction CT Imaging.
نویسندگان
چکیده
PURPOSE Iterative reconstruction (IR) technique is growingly used in clinical CT imaging due to its ability to provide improved image quality at lower patient doses. However, the nonlinear frequency response of IR technique, which may affect quantitative analysis, is rarely explored. This study evaluates noise level and contrast dependent behavior of MTF in IR CT imaging with a multi-contrast slit phantom scanned at different dose levels. METHODS A multi-contrast slit phantom was created consisting of acrylic panel and aluminum foils of different thickness. Images were acquired on multi-detector CT (Discovery CT750 HD: GE) at two dose levels (10mAs and 200mAs), and were reconstructed using FBP and two IR technique (ASIR50 and VEO). Line spread functions were extracted across slits of two different thickness (80um and 144um) on images scanned at two dose levels, and were Fourier transformed to evaluate the MTFs of IR and FBP reconstruction techniques, producing a total of 12 MTF curves. RESULTS MTF of 200mAs scan showed clearly higher responses up to 28% than that of 100mAs scan in VEO, marginally higher values up to 5% in ASIR50, and were in good agreement in FBP. At same dose level, the MTFs with higher contrast slit (144um) showed marginally higher response than that of lower contrast slit (80um) in VEO and ASIR50. CONCLUSIONS Our study revealed that MTF of IR technique degrades depending on noise level at low dose scan. Therefore, we recommend that its characteristic should be considered in quantitative analysis such as lesion size measurement.
منابع مشابه
Design and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملImaging performance in differential phase contrast CT compared with the conventional CT–Noise equivalent quanta NEQ(k)
The grating-based x-ray differential phase contrast (DPC) CT is emerging as a new technology with the potential for extensive preclinical and clinical applications. In general, the performance of an imaging system is jointly determined by its signal property (modulation transfer function–MTF(k)) and noise property (noise power spectrum–NPS(k)), which is characterized by its spectrum of noise eq...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملRadiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study
BACKGROUND To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). METHODS Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part4 شماره
صفحات -
تاریخ انتشار 2012