Assessment of central venous catheterization in a simulated model using a motion-tracking device: an experimental validation study.
نویسندگان
چکیده
BACKGROUND Central venous catheterization (CVC) is a basic requirement for many medical specialties. Simulated training in CVC may allow the acquisition of this competency but few reports have established a valid methodology for learning and acquiring procedural skills for CVC. This study aims to validate the use of a tracking motion device, the imperial college surgical assessment device (ICSAD), by comparing it with validated global rating scales (GRS) to measure CVC performance in a simulated torso. METHODS Senior year medical students, first and last year residents (PGY1, LYR), and expert anesthesiologists performed a jugular CVC assessment in a simulated model (Laerdal IV Torso). A validated GRS for objective assessment of technical skills and motion analysis by ICSAD was used. Statistical analysis was performed through Mann-Whitney and Kruskal-Wallis tests for construct validity and Spearman correlation coefficients between the ICSAD and GRS scores for concurrent validity between both. RESULTS 32 subjects were recruited (10 medical students, 8 PGY1, 8 LYR and 8 experts). Total path length measured with ICSAD and GRS scores were significantly different between all groups, except for LYR compared to experts (p = 0.664 for GRS and p = 0.72 for ICSAD). Regarding jugular CVC procedural time, LYR and experts were faster than PGY1 and MS (p < 0.05). Spearman correlation coefficient was -0.684 (p < 0.001) between ICSAD and GRS scores. CONCLUSIONS ICSAD is a valid tool for assessment of jugular CVC since it differentiates between expert and novice subjects, and correlates with a validated GRS for jugular CVC in a simulated torso.
منابع مشابه
Survey of a Practical Approach to Central Venous Catheterization in Pediatric Patients
Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...
متن کاملDesigning, validation, and reliability assessment of software to acquire kinematics parameters of motion by image processing
Motion analysis systems are useful and effective equipment in biomechanics research. Unfortunately these systems are available for few researchers because these are expensive equipment. The aim of this study was to design and validation of a practical and inexpensive software, to determine the exact markers position in space and compute the kinematic of movement. In designing the software, the ...
متن کاملMultiple Target Tracking With a 2-D Radar Using the JPDAF Algorithm and Combined Motion Model
Multiple target tracking (MTT) is taken into account as one of the most important topics in tracking targets with radars. In this paper, the MTT problem is used for estimating the position of multiple targets when a 2-D radar is employed to gather measurements. To do so, the Joint Probabilistic Data Association Filter (JPDAF) approach is applied to tracking the position of multiple targets. To ...
متن کاملESTIMATING THE STRONG-MOTION OF THE DECEMBER 26, 2003 BAM (IRAN), EARTHQUAKE USING STOCHASTIC TECHNIQUES
Abstract : The main objective of this study is estimating the strong motion for the Bam region using the stochastically based seismological models. The two widely used synthetic techniques namely point-source and finite-fault were utilized incorporating the source-path and site parameters into simple function. The decay factor kappa was estimated based on the data obtained from recorded stron...
متن کاملUsing the Adaptive Frequency Nonlinear Oscillator for Earning an Energy Efficient Motion Pattern in a Leg- Like Stretchable Pendulum by Exploiting the Resonant Mode
In this paper we investigate a biological framework to generate and adapt a motion pattern so that can be energy efficient. In fact, the motion pattern in legged animals and human emerges among interaction between a central pattern generator neural network called CPG and the musculoskeletal system. Here, we model this neuro - musculoskeletal system by means of a leg - like mechanical system cal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of surgical innovation and research
دوره 10 شماره
صفحات -