Biomechanical study on different lengths of PFNA fixation for unstable intertrochanteric femoral fractures
نویسندگان
چکیده
OBJECTIVE The aim of our study was to compare the biomechanical stability of the Proximal Femoral Nail Antirotation (PFNA) (with 200 mm, 240 mm and 280 mm-long main nails) for the management of unstable intertrochanteric femoral fractures. METHODS Tronzo-Evans Type IV and V fractures were built by applying a three-dimensional finite element model. Further, PFNA-II with 200 mm, 240 mm and 280 mm-long main nails were applied for fixation. The above model is the creation of 3 researchers designed in order to obtain average values of numerical stress. Von Mises stress distribution and medial and lateral stress peak of the femur and PFNA were compared. RESULTS 240 mm and 280 mm PFNA medial stress peak was reduced significantly in comparison to 200 mm PFNA (p⟨0.05). However, there was no difference between 240 mm and 280 mm PFN. Also, no statistical difference was observed with any of 3 lengths in both medial and lateral stress peak for Evans Type IV and V PFNA. CONCLUSION 240 mm and 280 mm PFNA could reduce femur fixation medial stress peak. Further, they were more efficient in comparison to the 200 mm PFNA, and their biomechanical stability was similar to that of the 280 mm nail.
منابع مشابه
Treatment of Unstable Intertrochanteric Fractureswith Proximal Femoral Nail Antirotation II: Our Experience in Indian Patients.
INTRODUCTION Unstable intertrochanteric fractures are difficult to manage and the choice of implant is critical for fracture fixation. The purpose of this study was to evaluate the functional and radiological outcome of proximal femoral nail antirotationII (PFNA II) in the treatment of unstable intertrochanteric fractures. MATERIALS AND METHODS We reviewed 45 patients of unstable intertrochan...
متن کاملDoes the PFNA™ nail limit impaction in unstable intertrochanteric femoral fracture? A 115 case-control series.
INTRODUCTION Femoral neck shortening after dynamic fixation of extra-capsular fracture may impair functional results, but is rarely assessed. The present study measured impaction in stable and unstable fractures (on the Ender classification) treated by PFNA™ nail. The objectives were: 1) to validate the Ender classification to assess fracture stability; 2) to determine whether neck shortening a...
متن کاملThe medial femoral wall can play a more important role in unstable intertrochanteric fractures compared with lateral femoral wall: a biomechanical study
BACKGROUND The major objective of the present study is to investigate the differences in the load and strain changes in the intertrochanteric region of human cadaveric femora between the loss of medial or lateral wall and after treatment with proximal femoral nail antirotation (PFNA). METHODS After measuring the geometry of the proximal femur region and modeling the medial or lateral wall def...
متن کاملCephalomedullary nail versus sliding hip screw for unstable intertrochanteric fractures in elderly patients.
PURPOSE To compare the short-term ambulatory function of elderly patients after fixation of unstable intertrochanteric fractures with either the AO-ASIF proximal femoral nail anti-rotation (PFNA) device or the dynamic hip screw (DHS). METHODS 63 patients aged 60 years or older underwent fixation for unstable intertrochanteric fractures (AO types A2 and A3) using the PFNA (n=25) or DHS (n=38)....
متن کاملThe Asia proximal femoral nail antirotation versus the standard proximal femoral antirotation nail for unstable intertrochanteric fractures in elderly Chinese patients.
BACKGROUND The best options of internal fixation for unstable intertrochanteric fractures in elderly Chinese patients remain controversial. The Asia proximal femoral nail antirotation (PFNA-II) was specifically designed for Asian patients, which could be more effective than the regular proximal femoral nail antirotation (PFNA). Compared to PFNA, whether PFNA-II is associated with shorter operat...
متن کامل