Hourly awakening vs continuous contact lens sensor measurements of 24-hour intraocular pressure: effect on sleep macrostructure and intraocular pressure rhythm.

نویسندگان

  • Florent Aptel
  • Renaud Tamisier
  • Jean-Louis Pépin
  • Benjamin Mottet
  • Ralitsa Hubanova
  • Jean-Paul Romanet
  • Christophe Chiquet
چکیده

IMPORTANCE All studies of 24-hour intraocular pressure (IOP) rhythm conducted to date have used repeated IOP measurements requiring nocturnal awakenings, potentially disturbing sleep macrostructure. OBJECTIVE To evaluate the effects on sleep architecture and IOP rhythm of hourly awakening vs a contact lens sensor (CLS) to continuously monitor IOP without awakening. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional study at a referral center of chronobiology among 12 young healthy volunteers, with a mean (SD) age of 22.3 (2.3) years. INTERVENTIONS Volunteers underwent two 24-hour IOP measurement sessions during a 2-month period. The eye order and session order were randomized. During one session, the IOP of the first eye was continuously monitored using a CLS, and the IOP of the fellow eye was measured hourly using a portable noncontact tonometer (session with nocturnal hourly awakening). During the other session, the IOP of the first eye was continuously monitored using a CLS, and the IOP of the fellow eye was not measured (session without nocturnal awakening). Overnight polysomnography was performed during the 2 sessions. MAIN OUTCOMES AND MEASURES A nonlinear least squares, dual-harmonic regression analysis was used to model the 24-hour IOP rhythm from the CLS data. Comparisons of acrophase, bathyphase, amplitude, and the midline estimating statistic of rhythm were used to evaluate the effect of hourly awakening on IOP rhythm. To evaluate the effects of hourly awakening on sleep architecture, comparisons of sleep structure were used, including total sleep period, rapid eye movement, wake after sleep onset, absolute and relative total sleep time, and non-rapid eye movement sleep (N1, N2, and N3). RESULTS A 24-hour IOP rhythm was found in all individuals for the sessions with and without awakening (P < .05). Hourly awakening for nocturnal IOP measurements increased wake after sleep onset (P = .04) but did not seem to change total sleep time, total sleep period, sleep efficiency, or slow-wave and rapid eye movement sleep stage duration (P > .30). Hourly awakening during noncontact tonometer IOP measurements did not seem to alter the mean variables of the 24-hour IOP pattern evaluated using CLS, including signal, maximum signal, minimum signal, acrophase, and bathyphase (P > .15). CONCLUSION AND RELEVANCE The 24-hour IOP rhythms seem to be unaffected by hourly nocturnal awakening for IOP measurements in young healthy individuals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor.

IMPORTANCE This study evaluates a new device that has been proposed to continuously monitor intraocular pressure (IOP) over 24 hours. OBJECTIVE To evaluate 24-hour IOP rhythm reproducibility during repeated continuous 24-hour IOP monitoring with noncontact tonometry (NCT) and a contact lens sensor (CLS) in healthy participants. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional study of 12 y...

متن کامل

Relationship Between Nocturnal Intraocular Pressure Variations and Sleep Macrostructure.

PURPOSE The purpose of this study was to characterize the relationships between nocturnal intraocular pressure (IOP) variations and sleep macrostructure in healthy subjects. METHODS This was a cross-sectional study conducted in a center with shared expertise in chronobiology. Twelve healthy volunteers (22.3 ± 2.3 years) underwent a 24-hour IOP measurement session. The IOP variations of one ey...

متن کامل

Frequent loss of nyctohemeral rhythm of intraocular pressure restored by nCPAP treatment in patients with severe apnea.

OBJECTIVE To assess 24-hour intraocular pressure (IOP) and ocular perfusion pressure rhythms in newly diagnosed apneic patients before and after nasal continuous positive airway pressure (nCPAP) treatment. METHODS Intraocular pressure (using a Tonopen XL) and ambulatory blood pressure, measured hourly for 24 hours, were analyzed in 18 consecutive patients with obstructive sleep apnea for nyct...

متن کامل

Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma.

OBJECTIVE To examine the safety, tolerability, and reproducibility of intraocular pressure (IOP) patterns during repeated continuous 24-hour IOP monitoring with a contact lens sensor. METHODS Forty patients suspected of having glaucoma(n=21) or with established glaucoma (n=19) were studied.Patients participated in two 24-hour IOP monitoring sessions (S1 and S2) at a 1-week interval (SENSIMED ...

متن کامل

The Fluctuation of Intraocular Pressure Measured by a Contact Lens Sensor in Normal-Tension Glaucoma Patients and Nonglaucoma Subjects.

PURPOSE We compared the fluctuation of intraocular pressure (IOP) in normal-tension glaucoma (NTG) patients and individuals with nonglaucoma eyes. We obtained continuous IOP values using a SENSIMED Triggerfish contact lens sensor. MATERIALS AND METHODS The eyes of 12 nonglaucoma subjects and 14 NTG patients were examined. In all 26 subjects, the IOP fluctuation was measured continuously for 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 132 10  شماره 

صفحات  -

تاریخ انتشار 2014