Monte Carlo modeling of cascade gamma rays in (86)Y PET imaging: preliminary results.
نویسندگان
چکیده
(86)Y is a PET agent that could be used as an ideal surrogate to allow personalized dosimetry in (90)Y radionuclide therapy. However, (86)Y also emits cascade gamma rays. We have developed a Monte Carlo program based on SimSET (Simulation System for Emission Tomography) to model cascade gamma rays in PET imaging. The new simulation was validated with the GATE simulation package. Agreements within 15% were found in spatial resolution, apparent scatter fraction (ratio of coincidences outside peak regions in line source sinograms), single and coincidence statistics and detected photons energy distribution within the PET energy window. A discrepancy of 20% was observed in the absolute scatter fraction, likely caused by differences in the tracking of higher energy cascade gamma photons. On average, the new simulation is 6 times faster than GATE, and the computing time can be further improved by using variance reduction techniques currently available in SimSET. Comparison with phantom acquisitions showed agreements in spatial resolutions and the general shape of projection profiles; however, the standard scatter correction method on the scanner is not directly applicable to (86)Y PET as it leads to incorrect scatter fractions. The new simulation was used to characterize (86)Y PET. Compared with conventional (18)F PET, in which major contamination at low count rates comes from scattered events, cascade gamma-involved events are more important in (86)Y PET. The two types of contaminations have completely different distribution patterns, which should be considered for the corrections of their effects. Our approach will be further improved in the future in the modeling of random coincidences and tracking of high-energy photons, and simulation results will be used for the development of correction methods in (86)Y PET.
منابع مشابه
Study of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method
Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...
متن کاملDesign and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling
Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...
متن کاملBremsstrahlung imaging from the liver using the Monte Carlo simulation
Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...
متن کاملMonte Carlo Study of Several Concrete Shielding Materials Containing Galena and Borated Minerals
Introduction: The heavyweight concretes have been widely used for constructing medical or industrial radiation facilities with photon sources. Materials and Methods: In this study, heavy concretes containing galena (PbS) and several borated minerals are proposed as suitable materials against photons. The shielding properties of 21 galena concretes containing seven borated minerals with three m...
متن کاملA Monte Carlo Study on the Shielding Properties of a Novel Polyvinyl Alcohol (PVA)/WO3 Composite, Against Gamma Rays, Using the MCNPX Code
Background: In recent years, there has been an increased interest toward non-lead radiation shields consisting of small-sized filler particles doped into polymer matrices. In this paper, we study a new polyvinyl alcohol (PVA)/WO3 composite in the presence of high-energy gamma photons through simulation via the Monte Carlo N-Particle (MCNP) simulation code. Materia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 54 13 شماره
صفحات -
تاریخ انتشار 2009