Sterilization of ginseng using a high pressure CO2 at moderate temperatures.
نویسندگان
چکیده
The aim of this study was to determine the feasibility of using high pressure CO2 for sterilization of Ginseng powder, as an alternative method to conventional techniques such as gamma-irradiation and ethylene oxide. The Ginseng sample used in this study was originally contaminated with fungi and 5 x 10(7) bacteria/g that was not suitable for oral use. This is the first time that high pressure CO2 has been used for the sterilization of herbal medicine to decrease the total aerobic microbial count (TAMC) and fungi. The effect of the process duration, operating pressure, temperature, and amount of additives on the sterilization efficiency of high pressure CO2 were investigated. The process duration was varied over 15 h; the pressure between 100 and 200 bar and the temperature between 25 and 75 degrees C. A 2.67-log reduction of bacteria in the Ginseng sample was achieved after long treatment time of 15 h at 60 degrees C and 100 bar, when using neat carbon dioxide. However, the addition of a small quantity of water/ethanol/H2O2 mixture, as low as 0.02 mL of each additive/g Ginseng powder, was sufficient for complete inactivation of fungi within 6 h at 60 degrees C and 100 bar. At these conditions the bacterial count was decreased from 5 x 10(7) to 2.0 x 10(3) TAMC/g complying with the TGA standard for orally ingested products. A 4.3 log reduction in bacteria was achieved at 150 bar and 30 degrees C, decreasing the TAMC in Ginseng sample to 2,000, below the allowable limit. However, fungi still remained in the sample. The complete inactivation of both bacteria and fungi was achieved within 2 h at 30 degrees C and 170 bar using 0.1 mL of each additive/g Ginseng. Microbial inactivation at this low temperature opens an avenue for the sterilization of many thermally labile pharmaceutical and food products that may involve sensitive compounds to gamma-radiation and chemically reactive antiseptic agents.
منابع مشابه
Solubility of CO2 in Aqueous Solutions of Diethanolamine (DEA) and Choline Chloride
In this study, the solubility of CO2 in DEA in the presence and absence of choline chloride was reported at different temperatures of 276.15, 298.15, 313.15, and 333.15 K, and pressure range of 4-15 bar. The solubility of CO2 was evaluated using the pressure decay method in a batch isochoric stirred absorption cell. Also, the design of experiments performed with Qualitek-4 software using the Ta...
متن کاملModeling of Pressure Dependence of Interfacial Tension Behaviors of Supercritical CO2 + Crude Oil Systems Using a Basic Parachor Expression
Parachor based expressions (basic and mechanistic) are often used to model the experimentally observed pressure dependence of interfacial tension (IFT) behaviors of complex supercritical carbon dioxide (sc-CO2) and crude oil mixtures at elevated temperatures. However, such modeling requires various input data (e.g. compositions and densities of the equilibrium liquid and vapor phases, and molec...
متن کاملUltrasonic synergistic effects in liquid-phase chemical sterilization.
New methods of sterilization employing a chemical with moderate heat and ultrasonic energy have been devised. Inactivation of high-density bacterial spore suspensions is achieved by treatment with low concentration aqueous acid glutaraldehyde solutions at temperatures above or about 54 C. Low (20 kHz) or high (250 kHz) frequency ultrasonic energy is synergistic with glutaraldehyde. Rapid inacti...
متن کاملHigh hydrostatic pressure
The use of high pressure processing (HPP) in the food industry was developed as an alternative to common thermal processes, such as pasteurization and sterilization, to produce a microbiologically safe food while avoiding and reducing undesirable changes in sensory, physiochemical and nutritional properties of foods. The use of high pressure at high temperatures as a tool for sterilization (hig...
متن کاملSimultaneous Measurement of Carbon Dioxide-Induced Swelling and Gas Sorption in Poly(methyl methacrylate) and Polystyrene
UNILAB, State Key Laboratory of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China Abstract: This paper deals with the swelling of Poly(methyl methacrylate) and Polystyrene samples in supercritical carbon dioxide in-situ at various temperatures and pressures by using directly optical observation. High pressure cell assembled with microscope and digital...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biotechnology and bioengineering
دوره 102 2 شماره
صفحات -
تاریخ انتشار 2009