Transepithelial Corneal Cross-Linking With Vitamin E-Enhanced Riboflavin Solution and Abbreviated, Low-Dose UV-A: 24-Month Clinical Outcomes
نویسندگان
چکیده
PURPOSE To report the clinical outcomes with 24-month follow-up of transepithelial cross-linking using a combination of a D-alpha-tocopheryl polyethylene-glycol 1000 succinate (vitamin E-TPGS)-enhanced riboflavin solution and abbreviated low fluence UV-A treatment. METHODS In a nonrandomized clinical trial, 25 corneas of 19 patients with topographically proven, progressive, mild to moderate keratoconus over the previous 6 months were cross-linked, and all patients were examined at 1, 3, 6, 12, and 24 months. The treatments were performed using a patented solution of riboflavin and vitamin E-TPGS, topically applied for 15 minutes, followed by two 5-minute UV-A treatments with separate doses both at fluence below 3 mW/cm(2) that were based on preoperative central pachymetry. RESULTS During the 6-month pretreatment observation, the average Kmax increased by +1.99 ± 0.29 D (diopter). Postoperatively, the average Kmax decreased, changing by -0.55 ± 0.94 D, by -0.88 ± 1.02 D and by -1.01 ± 1.22 D at 6, 12, and 24 months. Postoperatively, Kmax decreased in 19, 20, and 20 of the 25 eyes at 6 months, 12 months, and 24 months, respectively. Refractive cylinder was decreased by 3 months postoperatively and afterward, changing by -1.35 ± 0.69 D at 24 months. Best spectacle-corrected visual acuity (BSCVA) improved at 6, 12, and 24 months, including an improvement of -0.19 ± 0.13 logarithm of the minimum angle of resolution units at 24 months. There was no reduction in endothelial cell count. No corneal abrasions occurred, and no bandage contact lenses or prescription analgesics were used during postoperative recovery. CONCLUSIONS Transepithelial cross-linking using the riboflavin-vitamin E solution and brief, low-dose, pachymetry-dependent UV-A treatment safely stopped keratoconus progression.
منابع مشابه
The Biomechanical Effect of Corneal Collagen Cross-Linking (CXL) With Riboflavin and UV-A is Oxygen Dependent.
PURPOSE In an attempt to reduce treatment time in corneal collagen cross-linking (CXL) with riboflavin and ultraviolet-A (UV-A), recent protocol modifications include shorter irradiation times at higher fluence, while maintaining constant total applied energy (Bunsen-Roscoe law of reciprocity). While such parameter changes might produce similar biological results within a certain range, the lim...
متن کاملEvaluation of Intrastromal Riboflavin Concentration in Human Corneas after Three Corneal Cross-Linking Imbibition Procedures: A Pilot Study
Purpose. To compare stromal riboflavin concentration after three corneal cross-linking (CXL) imbibition procedures: standard (EpiOff), transepithelial corneal (EpiOn), and iontophoresis-assisted technique (Ionto) using 0.1% hypotonic riboflavin phosphate. Methods. Randomized open-label pilot clinical study. Twelve corneas/12 patients with advanced keratoconus were randomly divided into 4 groups...
متن کاملAnalytic Formulas for the Clinical Issues of a UV-Light-Activated Corneal Crosslinking Device
Objective: Modeling the critical issues of the dynamics of UV-light-initiated crosslinking of corneal collagen including the new safety criteria, crosslinking time and the efficacy. Methods: A coupled dynamic equations is numerically solved and analytic formulas are derived for three critical parameters: the safety dose (E*), the cross linking time (T*) and the efficacy defined by the increase ...
متن کاملSafety of corneal collagen cross-linking with UV-A and riboflavin in progressive keratoconus.
PURPOSE To assess the possible damage to ocular tissues during treatment of keratoconus with UV-A-riboflavin corneal collagen cross-linking (CXL). DESIGN Single center, prospective, interventional study. METHODS Fourteen eyes of 14 patients aged 28.2 ± 5.9 (mean ± SD) years with progressive keratoconus were treated with UV-A-riboflavin CXL. Corneal endothelium was assessed with the endothel...
متن کاملNovel myopic refractive correction with transepithelial very high-fluence collagen cross-linking applied in a customized pattern: early clinical results of a feasibility study
BACKGROUND The purpose of this study is to report the safety and efficacy of a new application of collagen cross-linking using a novel device to achieve predictable refractive myopic changes in virgin corneas. METHODS Four cases were treated with a novel device employing very high-fluence collagen cross-linking applied in a myopic pattern. Prior to treatment, riboflavin solution was applied t...