Relationship among eye and muzzle temperatures measured using digital infrared thermal imaging and vaginal and rectal temperatures in hair sheep and cattle.

نویسندگان

  • W D George
  • R W Godfrey
  • R C Ketring
  • M C Vinson
  • S T Willard
چکیده

Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of these experiments was to compare the temperature of the eye (EYE) or muzzle (MUZ) measured using DITI to vaginal (VT) and rectal temperature (RT) as measures of core body temperature in hair sheep and beef cattle. In Exp.1 EYE, VT and RT were measured in lactating, multiparous hair sheep ewes (St. Croix White, n = 10, and Dorper × St. Croix White, n = 10) in a non-febrile state 5 times over a 48-h period. Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.95), EYE and RT (r = 0.76) and EYE and VT (r = 0.77). In Exp. 2 EYE, MUZ, VT and RT were measured in multiparous, lactating ewes (St. Croix White, n = 2, and Barbados Blackbelly, n = 12) at -12, -1, 0, 1, 2, 3, 4, 6, 12, 24, 36, and 48 h after being administered lipopolysaccharide (LPS; n = 7; 0.2 µg/kg BW, i.v.) or saline (n = 7; 0.5 mL, i.v.). Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. When data were combined across treatments (LPS and saline) there was a high correlation (P < 0.001) between VT and RT (r = 0.96), EYE and RT (r = 0.82), MUZ and RT (r = 0.72), and EYE and VT (r = 0.93). In Exp. 3 EYE, MUZ, VT and RT were measured in multiparous, non-lactating, pregnant Senepol cattle (n = 44) between 0900 and 1200 h on a single day. A digital veterinary thermometer was used to measure both VT and RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.78), a moderate correlation (P < 0.001) between VT and EYE (r = 0.52), RT and EYE (r = 0.58) and EYE and MUZ (r = 0.48). There was no correlation (P > 0.10) between RT or VT and MUZ. The findings of these three studies indicate that temperature of the eye, measured using DITI, can be used as an indicator of core body temperature in hair sheep and beef cattle as an alternative to using vaginal or rectal temperature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی صحت و دقت دمای تمپانیک در بازتاب دمای مرکزی بدن

  Background & Aim: Monitoring of patients' temperature is an important nursing clinical procedure. Body temperature is usually taken at different sites including pulmonary artery, rectal, oral, and axillary areas. Currently, infrared tympanic temperature measurement method is increasingly used as a convenient, noninvasive and rapid method. However, accuracy and precision of this method has bee...

متن کامل

Digital Infrared Thermal Imaging and manual lameness scoring as a means for lameness detection in cattle

Accepted: 14/06/2014 Abstract Lameness is a serious issue in the dairy industry, both economically and from an animal welfare perspective. The incidence of lameness in UK herds has been estimated to be around 20-25%. The study looked at the use of Digital Infrared Thermal Imaging (DITI) and manual lameness scoring as a means for lameness detection in cattle. This was carried out at dairy unit i...

متن کامل

Thermoregulatory Mechanisms of Jersey Adult Cattle and Calves Based on Different Body Sites Temperature

In this experiment six healthy adult dairy Jersey cattles and eight calves (aged 4-6 months) were selected to measure temperature of different body skin sites, rectal temperature, respiration and heart rates during summer and winter. Body sites maximum and minimum temperature in calves during summer belonged to the ear, forehead, right flank, abdomen (38.4-38.9 ˚C) and carpus (32 ˚C). This was ...

متن کامل

O-19: A Comparison of Pelvic Magnetic Resonance Imaging, Trans-Vaginal and Trans-Rectal Sonography with Laparoscopic Findings in The Diagnosis of Deep Infiltrating Endometriosis

Background The performance of TVS, TRS and MRI for the diagnosis of DIE have been separately reported in earlier studies. However, the three methods have not been concurrently compared in terms of their overall performance and classified results as per different anatomical locations of DIE lesions in a large study population. This study was an attempt to compare pelvic magnetic resonance imagin...

متن کامل

A study of the relationship among temperatures of surface features and its application in remote sensing study of Lut desert

Physical characteristics of different features in desert is a reflection of severe thermal and climatic conditions. In this paper, diurnal surface temperature patterns of important surface features in Lut Desert were studied and the relationship among different surfaces analyzed. Diurnal trend in surface temperature of surface types, marl, dark sand, light sand, salt-affected soil, soul at 10 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 92 11  شماره 

صفحات  -

تاریخ انتشار 2014