Planar array infrared emission spectroscopy.

نویسندگان

  • Christian Pellerin
  • Isabelle Pelletier
  • John F Rabolt
  • D Bruce Chase
چکیده

Planar array infrared spectroscopy (PA-IR) is shown to be a powerful new approach to infrared emission spectroscopy (IRES). A proof-of-concept study of selected polymers indicates that PA-IRES allows acquisition of emission spectra with a high signal-to-noise ratio at temperatures as low as 80 degrees C. It is shown that a time resolution below 20 ms is readily achievable for time-resolved characterization of single non-repeatable events. The possibility of recording spatially resolved emission spectra is also demonstrated, and potential applications of this novel technique are finally described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved IR studies of monolayer self-assembly on a gold substrate using planar array infrared (PA-IR) spectroscopy.

Time-resolved and spatially resolved infrared spectra (line images) of self-assembled monolayers of octadecylthiol (ODT) on gold substrates were investigated by planar array infrared (PA-IR) spectroscopy, with a grazing incidence reflection attachment. It was observed that PA-IR spectra with a good signal-to-noise ratio that is comparable to those obtained from Fourier transform infrared spectr...

متن کامل

A faster approach to infrared rheo-optics using a planar array infrared spectrograph.

Infrared rheo-optics combines dynamic mechanical analysis with infrared spectroscopy to provide molecular level information about the segmental reorientation and the changes in local environment associated with the dynamic deformation of polymers. Up to now, the application of this technique has been limited by the amount of time necessary to perform the experiments. In this article, we demonst...

متن کامل

Performance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region.

A no-moving-part planar array infrared spectrograph (PA-IR) equipped with a 256 x 256 mercury cadmium telluride (MCT) focal plane array has been designed and constructed. The performance of the instrument, whose frequency range extends from 2000-975 cm(-1), has been assessed in terms of resolution, bandwidth, and signal-to-noise ratio. The PA-IR spectrograph is able to record spectra with an 8....

متن کامل

New developments in planar array infrared spectroscopy.

A planar array infrared (PA-IR) spectrograph offers several advantages over other infrared approaches, including high acquisition rate and sensitivity. However, it suffers from some important drawbacks, such as a limited spectral range and a significant curvature of the recorded spectral images, which still need to be addressed. In this article, we present new developments in PA-IR spectroscopy...

متن کامل

Infrared-red Cores in Nearby Elliptical Galaxies

We present the Spitzer Space Telescope Infrared Array Camera (IRAC) observations for a sample of local elliptical galaxies to study later stages of AGN activities. A sample of 36 elliptical galaxies is selected from the Palomar spectroscopic survey. We detect nuclear non-stellar infrared emission in 9 of them. There is unambiguous evidence of circumnuclear dust in these 9 galaxies in their opti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 79 5  شماره 

صفحات  -

تاریخ انتشار 2007