Treadmill and Cycle Ergometer Tests are Interchangeable to Monitor Triathletes Annual Training.
نویسندگان
چکیده
The purpose of this study was to verify the use of a single test to obtain annual training guidelines applicable to multiple modes of training. Eight triathletes (4 females, 4 males) were tested 3 times during their training year (Phase I; Phase II; Phase III) on a treadmill and cycle ergometer. Cardio-respiratory variables were calculated at standardized percentages of maximal oxygen uptake (VO2max; 50-100%). VO2max differences between tests reached 6% in every testing session (p ≤ 0.01). VO2max was stable for both tests throughout the season. The ANOVA (3 phases x 2 tests x 6 intensities) demonstrated that there was a significant difference for heart rate (HRs; p ≤ 0.05) between tests in Phase I only. However, the nonparametric sign test did not show any significant differences in any phase. These results demonstrated that triathletes could use the relationship between HR and % VO2max collected during a treadmill or a cycle ergometer test to obtain interchangeable reference HRs for monitoring their running and cycling training bouts in high volume and/or high intensity phases of their training year.
منابع مشابه
Ventilatory threshold and maximal oxygen uptake in present triathletes.
The aim of this study was to determine the physiological profile of young triathletes who began triathlon competition as their first sport. Twenty-nine male competitive triathletes (23 regionally and nationally ranked triathletes and 6 elite, internationally ranked triathletes) performed two tests, one on a cycle ergometer (CE VO2max) and one on a treadmill (TM VO2max). Results showed (a) no di...
متن کاملMaximal Lipid Oxidation (Fatmax) in Physical Exercise and Training: A review and Update
The exercise intensity, at which the maximal fat oxidation (MFO) rate occurs, has been defined as Fatmax. It has been suggested that the fat oxidation rate during the Fatmax intensity is approximately 2-fold greater than at any other intensity although modifiable by several physiological conditions (training, previous exercise or meal). There are a few standardized protocols for estimating of F...
متن کاملEstablishing Equivalence of Exercise Intensities
Introduction: Research trials that involve testing of physiological response to exercise and that include tests from more than one institution, or tests across long time periods, may be required to include tests from different ergometer types, mainly treadmill or leg cycle ergometer. The purpose of this study was to establish equivalence of metabolic demand when comparing treadmill to cycle erg...
متن کاملComparison of the ramp versus standard exercise protocols.
To compare the hemodynamic and gas exchange responses of ramp treadmill and cycle ergometer tests with standard exercise protocols used clinically, 10 patients with chronic heart failure, 10 with coronary artery disease who were asymptomatic during exercise, 11 with coronary artery disease who were limited by angina during exercise and 10 age-matched normal subjects performed maximal exercise u...
متن کاملSubmaximal cardiopulmonary thresholds on a robotics-assisted tilt table, a cycle and a treadmill: a comparative analysis
BACKGROUND The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 2 3 شماره
صفحات -
تاریخ انتشار 2003