A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements
نویسندگان
چکیده
PURPOSE To establish and validate a formula to predict spectral domain (SD)-optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness from time domain (TD)-OCT RNFL measurements and other factors. METHODS SD-OCT and TD-OCT scans were obtained on the same day from healthy participants and patients with glaucoma. Univariate and multivariate linear regression relationships were analyzed to convert average Stratus TD-OCT measurements to average Cirrus SD-OCT measurements. Additional baseline characteristics included age, sex, intraocular pressure, central corneal thickness, spherical equivalent, anterior chamber depth, optic disc area, visual field (VF) mean deviation, and pattern standard deviation. The formula was generated using a training set of 220 patients and then evaluated on a validation dataset of 105 patients. RESULTS The training set included 71 healthy participants and 149 patients with glaucoma. The validation set included 27 healthy participants and 78 patients with glaucoma. Univariate analysis determined that TD-OCT RNFL thickness, age, optic disc area, VF mean deviation, and pattern standard deviation were significantly associated with SD-OCT RNFL thickness. Multivariate regression analysis using available variables yielded the following equation: SD-OCT RNFL = 0.746 × TD-OCT RNFL + 17.104 (determination coefficient [R(2)] = 0.879). In the validation sample, the multiple regression model explained 85.6% of the variance in the SD-OCT RNFL thickness. CONCLUSIONS The proposed formula based on TD-OCT RNFL thickness may be useful in predicting SD-OCT RNFL thickness. Other factors associated with SD-OCT RNFL thickness, such as age, disc area, and mean deviation, did not contribute to the accuracy of the final equation.
منابع مشابه
Nerve fiber layer in glaucomatous hemifield loss: a case-control study with time- and spectral-domain optical coherence tomography.
PURPOSE To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. METHODS 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the ot...
متن کاملInfluence of Cataract Surgery on Measurements of Spectral Domain Optical Coherence Tomography
INFLUENCE OF CATARACT SURGERY ON MEASUREMENTS OF SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY Bambo et al evaluated the effect of uncomplicated cataract phacoemulsification on the measurements of macular and retinal nerve fibre layer (RNFL) using two spectral domain (SD) optical coherence tomography (OCT) instruments-Cirrus OCT (Zeiss) and Spectralis OCT (Heidelberg)-in 60 eyes healthy subjects...
متن کاملAutocalibration of spectral-domain optical coherence tomography spectrometers for in vivo quantitative retinal nerve fiber layer birefringence determination.
Accurate wavelength assignment of each spectral element for spectral-domain optical coherence tomography (SD-OCT) and optical frequency domain imaging (OFDI) is required for proper construction of biological tissue cross-sectional images. This becomes more critical for functional extensions of these techniques, especially in polarization-sensitive optical coherence tomography (PS-OCT), where in...
متن کاملAgreement of Two Different Spectral Domain Optical Coherence Tomography Instruments for Retinal Nerve Fiber Layer Measurements
PURPOSE To determine the agreement between Spectralis and Cirrus spectral domain optical coherence tomography (SD-OCT) measurements of peripapillary retinal nerve fiber layer (RNFL) thickness. METHODS Suspected or confirmed cases of glaucoma who met the inclusion criteria underwent peripapillary RNFL thickness measurement using both the Spectralis and Cirrus on the same day within a few minut...
متن کاملComparison of Retinal Nerve Fiber Layer Thickness Measurements in Healthy Subjects Using Fourier and Time Domain Optical Coherence Tomography
Purpose. To compare the retinal nerve fiber layer (RNFL) measurements using two different ocular coherence tomography (OCT) devices: Cirrus Fourier domain OCT and Stratus time domain OCT. To analyze reproducibility of Fourier domain measurements in healthy subjects. Methods. One hundred and thirty-two eyes of 132 healthy subjects were scaned on the same day with both instruments, separated by 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 26 شماره
صفحات -
تاریخ انتشار 2012