Clinical and dosimetric experience with MammoSite‐based brachytherapy under the RTOG 0413 protocol
نویسندگان
چکیده
MammoSite balloon brachytherapy is a relatively new technique for partial breast irradiation. The present paper focuses on the treatment planning, dosimetry, and quality assurance aspects of that treatment, based on the Radiation Therapy Oncology Group 0413 randomized prospective trial (RTOG 0413) protocol. We investigate the usefulness of evaluating implants for treatment appropriateness according to the full set of RTOG criteria as compared with the manufacturer's guidelines. We describe our methods to improve MammoSite balloon implants that would otherwise not comply with the protocol. The initially acquired computed tomography (CT) images are evaluated for tissue conformance, balloon surface-to-skin distance, and balloon symmetry. If the implant fails to meet the foregoing criteria, corrective action such as delay in the CT scan, balloon manipulation, or fluid volume adjustment is taken, and the patient is re-scanned. If the corrective action appears to be successful, three dimensional treatment planning and dose-volume histogram analysis is performed to evaluate the geometric and dosimetric parameters with regard to the RTOG 0413 protocol. The evaluated parameters include, volume ratio of the lumpectomy cavity to the ipsilateral breast, target volume coverage, tissue-balloon conformance, balloon symmetry, minimal balloon surface-to-skin distance, maximum skin dose, and normal breast tissue dose-volume parameters V150 and V200. Among our implants, 21.7% did not initially meet the RTOG 0413 acceptance criteria. Asymmetry and poor conformance values reduce the target volume coverage, and so an implant with moderate conformance and asymmetry can be within the manufacturer's guidelines, but still not meet the RTOG criteria. Our intervention corrected all but one of the implants that failed to meet the criteria. Manipulating the cavity and adjusting the balloon volume may salvage an implant and meet the strict geometric and dosimetric criteria imposed by the RTOG 0413 protocol.
منابع مشابه
Determination of Dosimetric characteristics of a New 192Ir-PDR Brachytherapy Source According to AAPM TG- 43 Protocol using Monte Carlo simulation technique
Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...
متن کاملEstimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code
Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...
متن کاملA Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy
Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...
متن کاملDosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code
Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...
متن کاملRecent developments in brachytherapy source dosimetry
Application of radioactive isotopes is the treatment of choice around the globe for many cancer sites. In this technique, the accuracy of the radiation delivery is highly dependent on the accuracy of radiation dosimetry around individual brachytherapy sources. Moreover, in order to have compatible clinical results, an identical method of source dosimetry must be employed across the world. This ...
متن کامل