Pathophysiology of ISR and mechanism of action of DES to prevent ISR
نویسندگان
چکیده
The development of stent has been a major advance in the treatment of obstructive coronary artery disease since the introduction of balloon angioplasty. However, neointimal hyperplasia occurring within the stent leading to in-stent restenosis is a main obstacle in the long-term success of percutaneous coronary intervention (PCI). The recent introduction of drug-eluting stents (DES) contributes a major breakthrough to interventional cardiology. Many large randomized clinical trials using DES have shown a remarkable reduction in angiographic restenosis and target vessel revascularization when compared with bare metal stents. The results of these trials also appear to be supported by evidence from everyday practice and noncontrolled clinical trials. However, the expanded applications of DES, especially in treating complex lesions such as left main trunk, bifurcation, saphenous vein graft lesions, or in-stent restenosis, are still under evaluation with ongoing studies. With the availability of different types of DES in the market, the issue of cost should not be a deterrent and DES will eventually be an economically viable option for all patients. The adoption of DES in all percutaneous coronary intervention may become a reality in the near future. In this review article, we summarize the recent development and progress of DES as well as compare and update the results of clinical trials.
منابع مشابه
Gene therapy for in-stent restenosis: Targets and delivery system
Center for Clinical & Translational Science, Creighton University School of Medicine, Omaha, Nebraska, USA Correspondence: Dr Devendra K Agrawal, Center for Clinical & Translational Science, Creighton University School of Medicine, CRISS II Room 510, 2500 California Plaza, Omaha, Nebraska 68178-0405, USA. Telephone 402-280-2938, fax 402-280-1421, e-mail [email protected] Despite the increased...
متن کاملAssociation of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent
In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...
متن کاملOptical coherence tomography characteristics of in-stent restenosis are different between first and second generation drug eluting stents☆
Aims Characterization of neointimal tissue is essential to understand the pathophysiology of in-stent restenosis (ISR) after drug eluting stent (DES) implantation. Using optical coherence tomography (OCT), we compared the morphologic characteristics of ISR between first and second generation DES. Methods and Results OCT was performed in 66 DES-ISR, defined as > 50% angiographic diameter steno...
متن کاملAssociation between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation.
AIMS Morphological assessment of neointimal tissue using optical coherence tomography (OCT) is important for clarifying the pathophysiology of in-stent restenosis (ISR) lesions. The aim of this study was to determine the impact of OCT findings on recurrence of ISR after various types of percutaneous coronary intervention (PCI) including plain old balloon angioplasty (POBA), paclitaxel-coated ba...
متن کاملBiological effect on drug distribution and vascular healing via paclitaxel‐coated balloon technology in drug eluting stent restenosis swine model
OBJECTIVES To evaluate the biological effect of a paclitaxel-coated balloon (PCB) technology on vascular drug distribution and healing in drug eluting stent restenosis (DES-ISR) swine model. BACKGROUND The mechanism of action and healing response via PCB technology in DES-ISR is not completely understood. METHODS A total of 27 bare metal stents were implanted in coronary arteries and 30 day...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -