Long-term persistence of polychlorinated dibenzo-p-dioxins and dibenzofurans in air, soil and sediment around an abandoned pentachlorophenol factory in China.

نویسندگان

  • Cheng Li
  • Minghui Zheng
  • Bing Zhang
  • Lirong Gao
  • Lidan Liu
  • Xin Zhou
  • Xiaodong Ma
  • Ke Xiao
چکیده

Air, soils and sediments surrounding an abandoned pentachlorophenol (PCP) factory were sampled to determine the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), unintentionally formed during PCP production. The mean concentration of PCDD/Fs in ambient air was one order of magnitude higher than that of the reference site. A trend of decreasing concentrations with increasing distance from the factory was observed, suggesting this site has a significant influence on the regional ambient air. As for soil samples collected within 3 km from the factory and sediment samples from the adjacent rivers, high levels of contamination were found with WHO-TEQ concentrations of 193 ± 211 pg/g and 667 ± 978 pg/g, respectively. The PCDD/F homologue profiles of all samples were consistent with those found in the technical product of PCP, with OCDD as the dominant congener. These results indicate PCDD/Fs in the historical contaminated site pose a long-term impact on surrounding environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chlorinated and brominated dibenzo-p-dioxins and dibenzofurans in surface sediment from Taihu Lake, China.

Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs) in surface sediment samples from Taihu Lake--an important water supply of the Yangtze River Delta, China--were investigated in the present study. Concentrations of PCDD/Fs ranged from 0.91 to 4.8 pg TEQ g(-1) dw (mean: 2.9 pg TEQ g(-1) dw, TEQ: Toxic Equivalent), which ...

متن کامل

Identifying contemporary and historic sources of soil

1 VIZARD, C.G, RIMMER, D.L, PLESS-MULLOLI, T, SINGLETON, I, & AIR, V.S. 2 Identifying contemporary and historic sources of soil polychlorinated dibenzo-p-dioxins 3 and polychlorinated dibenzofurans in an industrial urban setting. Science of the Total 4 Environment 2006, 370(1), 61-69. doi:10.1016/j.scitotenv.2006.06.006 5 6 Identifying contemporary and historic sources of soil 7 polychlorinated...

متن کامل

A simplified determination method of dioxin toxic equivalent (TEQ) by single GC/MS measurement of five indicative congeners.

Here, we proposed a simplified determination method for dioxin (polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls (PCBs)) toxic equivalency (TEQ; based on the World Health Organization-2006 toxicity equivalent factor) in environmental samples collected in Japan. This method has estimated the total TEQ from the concentrations of only five...

متن کامل

POLYCHLORINATED DIBENZO-p-DIOXINS AND DIBENZOFURANS AS PRODUCTS OF PHOTODEGRADATION OF CHLOROPHENOLS

Results of the study into photodegradation of 2,4,6-trichlorophenol and pentachlorophenol in aqueous solutions have been presented. Quantum yields and rate constants of the reactions were determined. Intermediate products were identified by GC/MS method. The experiments confirmed formation of polychlorinated dibenzo-p-dioxins and dibenzofurans in photochemical reactions. The findings showed tha...

متن کامل

Characterization and fate of polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in soils and sediments at the Portsmouth Gaseous Diffusion Plant, Ohio.

The U.S. Department of Energy Portsmouth Gaseous Diffusion Plant is in the early stages of decommissioning and decontamination. During operations, the site drew a large amount of electric power and had multiple large switchyards on site. These are a source of polychlorinated biphenyls (PCB) contamination to both on-site and off-site streams. Some soil remediation has been completed in the main ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental pollution

دوره 162  شماره 

صفحات  -

تاریخ انتشار 2012