Measurement of the x-ray mass attenuation coefficients of gold in the 38–50-keV energy range

نویسندگان

  • M. T. Islam
  • N. A. Rae
  • J. L. Glover
  • Z. Barnea
  • M. D. de Jonge
  • C. Q. Tran
  • J. Wang
  • C. T. Chantler
چکیده

We used synchrotron x rays to measure the x-ray mass attenuation coefficients of gold at nine energies from 38 to 50 keV with accuracies of 0.1%. Our results are much more accurate than previous measurements in this energy range. A comparison of our measurements with calculated mass attenuation coefficients shows that our measurements fall almost exactly midway between the XCOM and FFAST calculated theoretical values, which differ from one another in this energy region by about 4%, even though the range includes no absorption edge. The consistency and accuracy of these measurements open the way to investigations of the x-ray attenuation in the region of the L absorption edge of gold.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New consistency tests for high-accuracy measurements of X-ray mass attenuation coefficients by the X-ray extended-range technique.

An extension of the X-ray extended-range technique is described for measuring X-ray mass attenuation coefficients by introducing absolute measurement of a number of foils - the multiple independent foil technique. Illustrating the technique with the results of measurements for gold in the 38-50 keV energy range, it is shown that its use enables selection of the most uniform and well defined of ...

متن کامل

Measurement of the x-ray mass- attenuation coefficients of gold, derived quantities between 14 keV and 21 keV and determination of the bond lengths of gold

The x-ray mass-attenuation coefficients of gold are measured at 91 energies between 14 keV and 21 keV using synchrotron radiation. The measurements are accurate to between 0.08% and 0.1%. The photoelectric mass-absorption coefficients and the imaginary component of the form factors of gold are also determined. The results include the LI edge and are the most accurate and extensive gold dataset ...

متن کامل

Gamma-ray shielding properties for silicate glasses containing Bi2O3, PbO, and BaO

Introduction: With the extensive application of radiation sources and radioactive materials in various fields, the study of attenuation and absorption of X-rays and gamma-rays in several materials has become an essential and interesting field of research. Glass materials are possible alternatives of concretes for radiation-shielding materials.   Materials and Methods:...

متن کامل

Measurement of the X-ray mass attenuation coefficients of silver in the 5-20 keV range.

The X-ray mass attenuation coefficients of silver were measured in the energy range 5-20 keV with an accuracy of 0.01-0.2% on a relative scale down to 5.3 keV, and of 0.09-1.22% on an absolute scale to 5.0 keV. This analysis confirms that with careful choice of foil thickness and careful correction for systematics, especially including harmonic contents at lower energies, the X-ray attenuation ...

متن کامل

Radiation attenuation properties of shields containing micro and Nano WO3 in diagnostic X-ray energy range

Background: It has recently been shown that the particle size of materials used for radiation shielding can affect the magnitude of radiation attenuation. Over the past years, application of nano-structured materials in radiation shielding has attracted attention world-wide. The purpose of this study was to investigate the shielding properties of the lead-free shields containing micro and nano-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010