ToMFIR-based Detection and Estimation for Incipient Actuator Faults in a class of Closed-Loop Nonlinear Systems
نویسندگان
چکیده
Abstract: Since incipient faults often have small amplitudes and obscure symptoms, those observer-based or output residual-based fault indicators are ineffective for incipient faults, especially in the presence of system disturbances. The ToMFIR-based fault detection approaches use both controller and output residuals to construct a fault indicator, which make them sensitive to incipient faults. This paper extends the ToMFIR-based fault detection approaches to a class of closed-loop nonlinear systems under the consideration of system disturbances. The restriction on the fault type is removed compared with the existing approaches, and ToMFIR-based fault estimation algorithm has been derived. Verification results in a near space hypersonic vehicle (NSHV) simulation system can demonstrate the effectiveness of the proposed approach.
منابع مشابه
Sensor Fault Detection for a class of Uncertain Nonlinear Systems Using Sliding Mode Observers
This paper deals with the issues of sensor fault detection for a class of Lipschitz uncertain nonlinear system. By definition coordinate transformation matrix for system states and output system, at first the original system divided into two subsystems. the first subsystem includes uncertainties but without any sensor faults and the second subsystem has sensor faults but is free of uncertaintie...
متن کاملNonlinear Stabilizing Controller for a Special Class of Single Link Flexible Joint Robots
Joint flexibility is a very important factor to consider in the controller design for robot manipulators if high performance is expected. Most of the research works on control of flexible-joint robots in literature have ignored the actuator dynamics to avoid complexity in controller design. The problem of designing nonlinear controller for a class of single-link flexible-joint robot manipulator...
متن کاملEnhancing Data-based Fault Isolation Through Nonlinear Control
This work focuses on a broad class of nonlinear process systems subject to control actuator faults and disturbances and proposes a method for data-based fault detection and isolation that explicitly takes into account the design of the feedback control law. This method allows isolating specific faults in the closed-loop system; fault detection is done using a purely data-based approach and faul...
متن کاملControl Reconfiguration of a Boiler-Turbine Unit After Actuator Faults
Boiler-turbines are one of the most important parts in power generation plants. The safety problem in such systems has always been a special concern. This paper discusses the application of control reconfig uration by fault-hiding approach for a boiler-turbine unit. In Fault-hiding approach, after occurrence of a fault, nominal controller of the system remains unchanged; instead, a reconfigurat...
متن کاملReconfigurable Control of Hammerstein Systems after Actuator Faults
A new method for the control reconfiguration of stable Hammerstein systems after actuator faults is described. The class of Hammerstein systems contains input-saturated systems, which are ubiquitous in practice. The new reconfiguration approach uses a virtual actuator that permits to keep the nominal controller in the loop. The concept of virtual actuators is extended to reflect the nonlinear p...
متن کامل