Reference values for neonates and children for the UF-100 urine flow cytometer.
نویسندگان
چکیده
The UF-100 fully automated urine flow cytometer classifies urinary particles on the basis of their light scattering, fluorescence, and impedance properties. The UF-100 counts erythrocytes, leukocytes, bacteria, epithelial cells, and casts. The operating principles of the UF-100 and its precision, accuracy, and analytical sensitivity have been published previously (1–4). The high sensitivity of the flow cytometer leads to different reference values. In a recent report, Gyory et al. (5 ) presented reference values for children; for newborns, however, reference values have not as yet been published. In this report, we present preliminary reference values for neonates and children. To establish these reference ranges, samples from two groups of children were analyzed. The pediatricians considered the infants in the first group to have no afflictions of the urinary tract after studying the case history, laboratory values (e.g., creatinine and urea), and the urine test strip results (n 5 114). These infants were admitted to the neonatal clinic and remained there for .5 days. Admission automatically included urine examination in daily routine programs without additional consent of the parents. The long admission periods were attributable to other factors: maternal problems, such as cesarean section (n 5 57); or neonatal problems, such as atresia of the esophagus (n 5 3), inguinal hernia (n 5 5), atrio-ventricular canal (n 5 3), or preterm birth at more than 34 weeks of gestation without respiratory complications (n 5 46). Urine was collected using perineal stick-on plastic containers that were inspected every hour. Urine was also collected from preoperative children without evidence of hematuria, urinary tract infection (UTI), or renal disease (n 5 141) as evaluated by the case history, laboratory values (e.g., creatinine and urea), and test strip results from the laboratory. In each case, a pediatrician was the person evaluating the child. The surgical procedures were adenotomy (n 5 57), tonsillectomy (n 5 54), otocleisis (n 5 7), and correction of various forms of cheilognathouranoschisis (n 5 23). Three children were excluded because of UTI from unknown causes in the case history. Both groups that constituted the reference population were regarded as free of any afflictions of the kidney and the urinary tract. Both groups of samples were analyzed using the test strip analyzer Clinitek Atlas (Bayer Diagnostics) and the UF-100 urine flow cytometer (Sysmex). Results for flow cytometry were given in cells per microliter of urine. Pathological values were rechecked using not only the above mentioned analyzers but also in several cases by examination of the urinary sediment after centrifugation. This result was reported as cells/HPF (high-power field). The children were again clinically examined, and those with previously undetected UTIs or other diseases affecting the urogenital system were not included in the reference set. Because the values did not exhibit a gaussian distribution, the 5th and 95th percentiles were used as reference limits. The provisional reference values for healthy neonates (n 5 114) are shown in the upper portion of Table 1. For comparison, the results for erythrocytes and leukocytes obtained after centrifugation and microscopic analysis of the urinary sediment (0–2 cells/HPF and 0–3 cells/ HPF, respectively) are shown. The UF-100 measurements clearly gave higher cell counts for erythrocytes (;5 cells/mL) and leukocytes (;12 cells/mL). Epithelial cells were also counted by the UF-100, yielding a numerical value of ;4 cells/mL. When sediment microscopy was used, only the presence of epithelial cells was reported. Casts were not usually present. Practically all urine samples examined exhibited the presence of bacteria. Thus, a relatively high cell count (;83 cells/mL) was obtained. Preanalytical factors such as storage time before analysis certainly affect this result. The reference values obtained for children (n 5 141) are also shown in the lower portion of Table 1. Slightly higher values for erythrocytes and leukocytes were obtained with the UF-100 (; 4 cells/mL for both eryth-
منابع مشابه
Unsatisfactory performance of flow cytometer UF-100 and urine strips in predicting outcome of urine cultures.
UF-100 flow cytometer and urine strip results were cross-interpreted to predict culture outcomes. The best negative predictive value was obtained with bacteria at > or =1,000/microl, white blood cells at > or =20/microl, or leukocyte esterase positivity. Nine of 24 false negatives were clinically significant. Thus, UF-100 and urine strip results do not accurately predict the outcome of cultures.
متن کاملAutomated flow cytometry compared with an automated dipstick reader for urinalysis.
Recently, the Sysmex UF-100 flow cytometer was developed to automate urinalysis. We compared UF-100 test results with those of an automated dipstick reader. A cross-check of UF-100, dipstick, and microscopic sediment data was performed in 1001 urine samples. Good agreements (P <0.001) were obtained between UF-100 and dipstick data for erythrocytes (r = 0.636) and leukocytes (r = 0.785). Even in...
متن کاملAutomated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.
BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...
متن کاملLeukocyte counts in cerebrospinal fluid with the automated hematology analyzer CellDyn 3500 and the urine flow cytometer UF-100.
BACKGROUND The counting of leukocytes and erythrocytes in cerebrospinal fluid (CSF) is still performed microscopically, e.g., using a chamber in most laboratories. This requires sufficient practical experience, is time-consuming, and may constitute a problem in emergency diagnostics. Specific automated systems for CSF cell counting are not available at present. METHODS We tested the hematolog...
متن کاملEvaluation of the Sysmex UF-100 urine cell analyzer as a screening test to reduce the need for urine cultures for community-acquired urinary tract infection.
We evaluated the UF-100 flow cytometer (TOA Medical Electronics, Kobe, Japan) as a screening test for community-acquired urinary tract infection (UTI) to reduce the need for bacterial cultures. By comparing the test results for 330 urine samples with quantitative urine cultures, we established cutoff criteria for the UF-100. To rule out hospital-acquired UTI, all urine samples were from new pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 45 10 شماره
صفحات -
تاریخ انتشار 1999