Fructosamine Clinical Usefulness and Determination of Reference Ranges

نویسنده

  • Carl W. Ludvigsen
چکیده

Fructosamine measurement, on the other hand, exploits the ability of serum proteins to undergo glycation (glycosylation) in conditions of increased ambient glycemia. Glycated proteins are an accepted measure of intermediate glycemia2,3 as demonstrated by the well established clinical usage of hemoglobin A determinations. Serum proteins are glycated as well, and determinationlc of their values reflect time-integrated glucose concentrations over the twoto fourweek half-life of these serum proteins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of reference ranges using medical laboratory date

In order to have reliable reference ranges and to minimize the effects of variables such as the procedure of specimen collection, geographical location, dietary habits, life style and possible errors during the performance of tests, it  is recommended that each medical laboratory establish it's own reference values. Idealy, the reference ranges Should be determined by analysis of specimens from...

متن کامل

Laboratory assessment of a commercial kit for measuring fructosamine in serum.

We have evaluated the laboratory performance and clinical usefulness of the Roche fructosamine kit. As used with an Abbott ABA 100 bichromatic analyzer, the kit response varied linearly with fructosamine concentration to 5.0 mmol/L (deoxymorpholinofructose equivalents). Interbatch precision was 4.1% and 3.6% for respective fructosamine concentrations of 3.2 and 5.0 mmol/L; intrabatch precision ...

متن کامل

Fructosamine: structure, analysis, and clinical usefulness.

Glucose molecules are joined to protein molecules to form stable ketoamines, or fructosamines, through glycation, a nonenzymatic mechanism involving a labile Schiff base intermediate and the Amadori rearrangement. The amount of fructosamine in serum is increased in diabetes mellitus owing to the abnormally high concentration of sugar in blood. The concentration of fructosamine in serum thus ref...

متن کامل

Age Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men

Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...

متن کامل

Reference values for fructosamine concentrations in children's sera: influence of protein concentration, age, and sex.

Fructosamine and protein (total and fractionated) were measured in the serum of 170 normal children, ages two weeks to 15 years. The mean fructosamine concentration was 2.12 mmol/L, 5% lower than the mean value observed for adults. We observed no sex-related difference in fructosamine values, but saw a pronounced age dependency of reference values. For children younger than three years, the mea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005