Oximeter performance: the influence of acquisition parameters.
نویسندگان
چکیده
STUDY OBJECTIVE This study was designed to determine whether different desaturation indexes (DIs) would be obtained in patients with sleep-disordered breathing by systematically altering two acquisition parameters: the recording setting and the display mode. DESIGN Prospective clinical study. SETTING Community sleep-disorders center. PATIENTS The study included 75 patients who were suspected of having sleep-disordered breathing. INTERVENTIONS Each patient had simultaneous pulse oxyhemoglobin saturation (SpO2) traces at three recording settings (3 s, 6 s, and 12 s) during the diagnostic phase of split-night polysomnography. On-line and memory displays of those data at each recording setting were obtained. DIs for > or = 3% desaturation events per hour were calculated for each of the six traces. RESULTS The mean on-line DIs significantly differed from each other, with slower (longer) recording settings resulting in lower values than faster (shorter) settings. The memory DIs all significantly underestimated the on-line DIs. Pearson correlations ranged from 0.82 to 0.90 between the on-line/memory DI pairs, but Bland-Altman analysis detected disagreement at higher levels of disordered breathing. CONCLUSIONS These findings confirm that significantly different SpO2 data are obtained at various acquisition options. The recording setting and display mode parameters should be disclosed in all reports employing oximetry with the fastest recording setting and on-line display mode preferable for case finding of sleep-disordered breathing.
منابع مشابه
Mobile Health Monitoring System
A mobile health monitoring system for physiological studies and for assisting patient-centric health care management is developed. Pulse oximeter and temperature sensor are employed for data acquisition along with appropriate design of signal conditioning circuit. The system uses network approach to acquire the data from sensors and transmit them to a server through wireless propagation means. ...
متن کاملOximeter performance and diagnostic accuracy of sleep studies.
I am writing to comment on the article by Davila et al (November 2002), which highlighted the importance of understanding instruments, mainly oximeters in his example, when acquiring data to be used in medical diagnosis. Davila and colleagues1 showed that, depending on the acquisition parameters set on the instrument and the mechanism of storage of the data, the results of variables such as oxy...
متن کاملThe effects of motion on the performance of pulse oximeters in volunteers (revised publication).
BACKGROUND Pulse oximetry is considered a standard of care in both the operating room and the postanesthetic care unit, and it is widely used in all critical care settings. Pulse oximeters may fail to provide valid SpO2 data in various situations that produce low signal-to-noise ratio. Motion artifact is a common cause of oximeter failure and loss of accuracy. This study compares the accuracy a...
متن کاملPerformance Analysis of an Industrial Robot Under Uniform Temperature Change
The effect of temperature change on dynamic performances of an industrial robot with six axes of freedom is studied in this paper. In general, the strain and stress are produced not only by the external exciting force, but also by temperature change. The strain energy that is caused by temperatureThis paper describes how the temperature variation effects the dynamic performance of an indu...
متن کاملInfluence of Feed Withdrawal for Three Hour Time Period on Growth Performance and Carcass Parameters Later Stage of Male Broiler Chickens
Feed restriction strategies are proven to be effective in increasing the growth performance and carcass parameters of broiler chickens. The objective of the present experiment was to evaluate the effects of feedremoval for three hour time periodon growth performance and carcass parameters of relatively older male broiler chickens. Twenty days old male broiler chickens (n=80) were allocated into...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 122 5 شماره
صفحات -
تاریخ انتشار 2002