Ultrasonic anisotropy measured in 2-dimensional echocardiograms in vitro and verified by histology.

نویسندگان

  • Junko Komata
  • Tokuhiro Kawara
  • Kazuyoshi Tanaka
  • Sera Hirota
  • Sayaka Nishi
  • Yuichiro Cho
  • Kenji Sato
  • Masato Matsuura
  • Itsuro Miyazato
چکیده

This study aims to validate ultrasonic anisotropy in 2-dimensional echocardiograms by one-to-one histological correlation. Thirteen echograms were obtained in vitro from 9 specimens of 2 left ventricles of healthy adult beagle dogs and were correlated with corresponding histology in regard to ultrasound orientation relative to the local fiber direction. Median value of pixel echogenicity (255-rank) was lower in areas with parallel (n = 9, 18 ± 13) than in those with oblique (n = 7, 41 ± 14, P < 0.05) and perpendicular (n = 13, 57 ± 21, P < 0.01) ultrasound orientations. Echogenicity in the proximal part within 0.5 cm from an edge was relatively high (n = 9, 33 ± 15; n = 5, 66 ± 27; n = 8, 65 ± 32, respectively) and was different between parallel and perpendicular orientations (P < 0.05). The ratio of the distal adjacent 0.5-cm part to the proximal part echogenicity was lower for either parallel or oblique orientation (0.35 ± 0.25, 0.51 ± 0.16) than for perpendicular orientation (0.95 ± 0.16, P < 0.01, respectively). Acoustic dropouts appeared beyond myocardial areas with parallel or oblique ultrasound orientation. These results disclosed precise acoustic anisotropy in the 2-dimensional echocardiograms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Assessing the Efficiency of Ultrasound Parameters in the Detection of Bone Repair Process

Introduction: The low regeneration of bone in defective bones causes therapeutic problems. Various strategies to assess the healing of bone defects have been used which they include histological and histo-chemical analysis in an invasive study. The purpose of this study was to determine the ultrasonic parameters of bone as a promising noninvasive technology for assessing bone repair process. Ma...

متن کامل

Finite element simulation of the clinching process of steel sheets and study on influence of anisotropy on the mechanical behavior of joint

This article describes a numerical study on the TOX-clinching process of the steel sheets. In addition, the influence of plastic anisotropy of the material on joining parameters is analyzed by evolution of the joint parameters such as undercut and neck thickness and punch force-displacement curve. Finite element analysis with ABAQUS/CAE-Explicit program is used to simulate two dimensional and t...

متن کامل

A sector scanner for real time two-dimensional echocardiography.

During the past several years one-dimensional pulse-echo ultrasound techniques have proven extremely useful in cardiac diagnosis. A one-dimensional system, however, only visualizes structures lying along a single straight line. The spatial relationships of the various cardiac structures are therefore not so easily defined as with two-dimensional systems which display the heart by constructing a...

متن کامل

Variation of left ventricular myocardial gray level on two-dimensional echocardiograms as a result of cardiac contraction.

Integrated ultrasonic backscatter from normal myocardium has been shown to vary with the phase of cardiac contraction (decreasing from end-diastole to end-systole) in previous studies of open-chest dogs. If confirmed, this finding would have important implications for clinical application of ultrasonic tissue characterization. Our hypothesis was that a cardiac cycle-dependent variation in regio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical and dental sciences

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2010