BACKGROUND A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA). Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA) for adaptive controller design and validation. METHODS MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. RESULTS The maximum speed of the bolus in the aorta ranged from 5-13 cm/s and the dwell time ranged from 7-13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. CONCLUSION The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance Angiography Techniques

■ ■ Contrast-Enhanced Magnetic Resonance Angiography t1 Shortening phase encoding Considerations acquisition timing acquisition timing: test Bolus acquisition timing: Signal Initiated acquisition acquisition timing: Dynamic Subtraction Contrast-enhanced Magnetic resonance angiography Imaging parameters advantages of Contrast-enhanced Magnetic resonance angiography Limitations of Contrast-enhanc...

متن کامل

The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality

OBJECTIVE To compare injector-based contrast agent (CA) administration with hand injection in magnetic resonance angiography (MRA). METHODS Gadobutrol was administered in 6 minipigs with 3 protocols: (a) hand injection (one senior technician), (b) hand injection (6 less-experienced technicians), and (c) power injector administration. The arterial bolus shape was quantified by test bolus measu...

متن کامل

Time-resolved noncontrast enhanced 4-D dynamic magnetic resonance angiography using multibolus TrueFISP-based spin tagging with alternating radiofrequency (TrueSTAR).

PURPOSE The goal of this study was to introduce a new noncontrast enhanced 4D dynamic MR angiography (dMRA) technique termed multibolus TrueFISP-based spin tagging with alternating radiofrequency (TrueSTAR). METHODS Multibolus TrueFISP-based spin tagging with alternating radiofrequency was developed by taking advantage of the phenomenon that the steady-state signal of TrueFISP is minimally di...

متن کامل

Comparison of dual to single contrast bolus magnetic resonance myocardial perfusion imaging for detection of significant coronary artery disease.

PURPOSE To investigate the incremental diagnostic value of dual-bolus over single-contrast-bolus first pass magnetic resonance myocardial perfusion imaging (MR-MPI) for detection of significant coronary artery disease (CAD). MATERIALS AND METHODS Patients (n = 49) with suspected CAD underwent first pass adenosine stress and rest MR-MPI and invasive coronary angiography (CA). Gadolinium diethy...

متن کامل

Steady-state magnetic resonance angiography of the thoracic vasculature in congenital heart disease using a blood pool contrast agent: evaluation of two different techniques

Background Although contrast-enhanced first-pass MRA (FP-MRA) is frequently used to visualize the vasculature, it may not be suitable for the assessment of congenital heart disease. Blood-pool contrast agents remain within the intravascular space for several hours, allowing vessels to be imaged without relying on accurate contrast bolus timing. The purpose of this study is to compare steadystat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2006