Femoral osteolysis around the unrevised stem during isolated acetabular revision.

نویسندگان

  • Byung-Woo Min
  • Kwang-Soon Song
  • Chul-Hyun Cho
  • Ki-Cheor Bae
  • Kyung-Jae Lee
چکیده

UNLABELLED Many surgeons treat progressive femoral osteolysis in association with a well-fixed stem with bone grafting but in uncontained proximal defects the graft could get into the joint, raising a question regarding whether the osteolysis can be treated by simple débridement without bone grafting. We investigated whether the curetted proximal osteolysis around an unrevised femoral component progressed in size and whether this lesion would have a deleterious effect on fixation of the femoral component in patients with isolated acetabular revision. We prospectively followed 21 patients (24 hips) who underwent acetabular revision and curetting of femoral osteolysis. The minimum followup was 3 years (mean, 4.3 years; range, 3-7.4 years). By the latest followup, no hips had major progression of the osteolytic defect through the followup period and none had any new osteolytic lesions. All hips were judged stable and to have well-fixed acetabular cups and femoral stems. Provided a femoral component is bone ingrown with osseointegration sufficient to provide long-term stability, the osteolytic defect is in the proximal aspect of the femur, and the defect is uncontained, simple curettage may preserve femoral implant stability and may prevent progression of osteolysis to another Gruen zone for at least 3 to 7 years. LEVEL OF EVIDENCE Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component.

A modular layered acetabular component (metal-polyethylene-ceramic) was developed in Japan for use in alumina ceramic-on-ceramic total hip replacement. Between May 1999 and July 2000, we performed 35 alumina ceramic-on-ceramic total hip replacements in 30 consecutive patients, using this layered component and evaluated the clinical and radiological results over a mean follow-up of 5.8 years (5 ...

متن کامل

The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age: a 12- to 16-year review.

We have reviewed 70 Harris-Galante uncemented acetabular components implanted as hybrid hip replacements with cemented stems between 1991 and 1995 in 53 patients whose mean age was 40 years (19 to 49). The mean follow-up was for 13.6 years (12 to 16) with no loss to follow-up. We assessed the patients both clinically and radiologically. The mean Oxford hip score was 20 (12 to 46) and the mean H...

متن کامل

Primary total hip arthroplasty without the use of bone cement: a 10-year follow-up of 157 hips.

BACKGROUND The cementless fixation technique in total hip arthroplasty (THA) was developed to solve clinical problems such as aseptic loosening and osteolysis which were thought to be associated with the use of bone cement. This retrospective study reports our mid-term results with cementless THA. METHODS A series of 173 consecutive, unselected cementless THA procedures using the Omnifit pros...

متن کامل

Isolated polyethylene exchange versus acetabular revision for polyethylene wear.

UNLABELLED Polyethylene wear and osteolysis are not uncommon in THA mid- and long-term. In asymptomatic patients the dilemma faced by the orthopaedic surgeon is whether to revise the cup and risk damage to the supporting columns and even pelvic discontinuity or to perform isolated polyethylene exchange and risk a high rate of postoperative recurrent instability and dislocation that will necessi...

متن کامل

A Minimum Ten-year Review from an Independent Centre

J Bone Joint Surg [Br] 2006;88-B:1584-90. Received 30 June 2006; Accepted after revision 15 August 2006 We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 467 6  شماره 

صفحات  -

تاریخ انتشار 2009