Accuracy of automated blood pressure monitors.
نویسندگان
چکیده
PURPOSE The purpose of this study is to determine if automated and aneroid manometers are as accurate a means of determining blood pressure as the mercury manometer. Obtaining vital signs for patients is considered standard of care, yet many dental offices do not routinely perform this health service because of technique inconsistencies and time constraints. The use of automatic blood pressure monitors addresses both concerns. The mercury column manometer, the control in this study, has long been considered the most accurate and preferred instrument for obtaining blood pressure measurements. METHODS During this study, 94 participants (19 years of age and older) consented to having blood pressure taken by each of 4 different monitors. These included the mercury column manometer and stethoscope, the aneroid manometer and stethoscope, the automatic arm blood pressure monitor, and the automatic wrist blood pressure monitor. Each of 3 investigators was assigned to and calibrated for a specific monitoring device. All measurements were taken from the left arm with 5 minutes allowed between measurements. Identical stethoscopes were used with the manual monitors. Strict adherence to the manufacturers' directions and patient preparation was followed for all monitors. Investigators were not aware of readings obtained by other investigators during testing. Eighty-three subjects completed all tests. RESULTS Review and analysis of data indicates little difference for pulse readings between the automated and digital methods. Systolic readings by automated wrist manometers were the most unreliable. Automated arm monitors tended to provide higher measures than the mercury standard on average, and demonstrated significantly different diastolic readings in one age group compared to the control. All monitors exhibited low reliability for participants over age 50 compared to the control. CONCLUSION This study demonstrates there is inaccuracy in the use of automated blood pressure monitors and traditional aneroid manometers when compared to the gold standard mercury column manometer for subjects of all ages and blood pressure ranges.
منابع مشابه
Noninvasive blood pressure monitoring.
For more 20 years, noninvasive blood pressure (NIBP) monitors have been widely used in operating rooms and critical care units to closely monitor blood pressure in patients of all ages. Despite the widespread use of automated blood pressure monitors, clinicians continue to deliberate over the accuracy and reliability of automated NIBP devices compared to other methods of blood pressure determin...
متن کاملElectromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors
Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...
متن کاملCan the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?
Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...
متن کاملImpact of atrial fibrillation on the accuracy of oscillometric blood pressure monitoring.
The introduction of automated oscillometric blood pressure monitors was the basis for today's widespread use of blood pressure self-measurement. However, in atrial fibrillation, there is a controversial debate on the use of oscillometry because there is a high variability of heart rate and stroke volume. To date, the accuracy of oscillometric blood pressure monitoring in atrial fibrillation has...
متن کاملHow Accurate Are Home Blood Pressure Devices in Use? A Cross-Sectional Study
BACKGROUND Out of office blood pressure measurements, using either home monitors or 24 hour ambulatory monitoring, is widely recommended for management of hypertension. Though validation protocols, meant to be used by manufacturers, exist for blood pressure monitors, there is scant data in the literature about the accuracy of home blood pressure monitors in actual clinical practice. We performe...