Wireless on-demand and networking of Puritan Bennett 840 ventilators for direct data capture.
نویسنده
چکیده
Manual transcription inaccuracies have been reported to be a frequent occurrence in clinical practice, which has been confirmed in my institution. I explored alternative methods of obtaining data directly from the Puritan Bennett ventilator. The aim of this project was to record all of the ventilator settings and monitored data with wireless technology. I evaluated 2 data-capture methods: on-demand data capture into a personal digital assistant, and continuous ventilator networking with a stand-alone computer. I was successful in both the intensive care unit and laboratory environment in transferring ventilator data, for up to several days, and with a data-capture interval as short as 60 seconds.
منابع مشابه
Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators.
BACKGROUND Calculation of total inspiratory resistance (Rtot) for patients on ventilatory support is typically based on measurement of airflow velocity and airway opening pressure during end-inspiratory occlusion by the inspiratory valve in the ventilator. Systematic error is introduced into Rtot measurements because the inspiratory valve closes over a period of time (not instantaneously, so ga...
متن کاملAccuracy of automatic tube compensation in new-generation mechanical ventilators.
OBJECTIVE To compare performance of flow-adapted compensation of endotracheal tube resistance (automatic tube compensation, ATC) between the original ATC system and ATC systems incorporated in commercially available ventilators. DESIGN Bench study. SETTING University research laboratory. SUBJECTS The original ATC system, Dräger Evita 2 prototype, Dräger Evita 4, Puritan-Bennett 840. INT...
متن کاملBench study on active exhalation valve performance.
BACKGROUND Ventilator exhalation-valve performance during the expiratory phase has been studied in depth. An active exhalation valve uses servo-control technology that allows gas to be released from the exhalation valve during the inspiratory phase if the patient makes an expiratory effort. We conducted a bench study of active exhalation valve response to expiratory effort during the inspirator...
متن کاملEffects of gas leak on triggering function, humidification, and inspiratory oxygen fraction during noninvasive positive airway pressure ventilation.
OBJECTIVES During noninvasive positive pressure ventilation (NPPV), the gas leak that commonly occurs around the mask can render NPPV ineffective. We evaluated the effects of gas leak on inspiratory trigger function during NPPV with bilevel pressure and ICU ventilators. In addition, we evaluated the effects of gas leak on fraction of inspired oxygen (Fio(2)) and humidification. METHODS Air le...
متن کاملDoes the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief?
OBJECTIVE An endotracheal tube (ETT) imposes work of breathing on mechanically ventilated patients. Using a bellows-in-a-box model lung, we compared the tube compensation (TC) performances of the Nellcor Puritan-Bennett 840 ventilator and of the Dräger Evita 4 ventilator. MEASUREMENTS AND RESULTS Each ventilator was connected to the model lung. The respiratory rate of the model lung was set a...