The thermal conductivity of polycrystalline magnesium oxide has been measured over the temperature range from 400 K to 1300 K using a modified guarded-hot-plate design. Three different thicknesses of specimens having 93 % of theoretical density were tested to verify the operation, accuracy, and reproducibility of our apparatus. The measured thermal conductivity ranges from 30 W · m-1 · K-1 down to 8 W · m-1 · K-1 and has an inverse-temperature functionality. The results agree well with literature values for this material.
منابع مشابه
Thermal Conductivity of a Zirconia Thermal Barrier Coating
The conductivity of a thermal-barrier coating composed of atmospheric plasma sprayed 8 mass percent yttria partially stabilized zirconia has been measured. This coating was sprayed on a substrate of 410 stainless steel. An absolute, steady-state measurement method was used to measure thermal conductivity from 400 to 800 K. The thermal conductivity of the coating is 0.62 W/(m⋅K). This measuremen...
متن کاملA Non-Steady-State Method of Measuring the Thermal Conductivity of Transparent Liquids
A plane source method has been developed for non-steady-state measurements of the thermal conductivity of transparent liquids. The plane source is realized by using an electrically heated metal foil, suspended in the liquid. The temperature distribution is described by using the concept of instantaneous heat sources giving a simple expression of the optical path, which is recorded with wave-fro...
متن کاملAbsolute Steady-State Thermal Conductivity Measurements by Use of a Transient Hot-Wire System
A transient hot-wire apparatus was used to measure the thermal conductivity of argon with both steady-state and transient methods. The effects of wire diameter, eccentricity of the wire in the cavity, axial conduction, and natural convection were accounted for in the analysis of the steady-state measurements. Based on measurements on argon, the relative uncertainty at the 95 % level of confiden...
متن کاملThermal Conductivity Measurement of an Electron-Beam Physical-Vapor-Deposition Coating
An industrial ceramic thermal-barrier coating designated PWA 266, processed by electron-beam physical-vapor deposition, was measured using a steady-state thermal conductivity technique. The thermal conductivity of the mass fraction 7 % yttria-stabilized zirconia coating was measured from 100 °C to 900 °C. Measurements on three thicknesses of coatings, 170 μm, 350 μm, and 510 μm resulted in ther...
متن کاملModified data analysis for thermal conductivity measurements of polycrystalline silicon microbridges using a steady state Joule heating technique.
Accurate knowledge of thermophysical properties is needed to predict and optimize the thermal performance of microsystems. Thermal conductivity is experimentally determined by measuring quantities such as voltage or temperature and then inferring a thermal conductivity from a thermal model. Thermal models used for data analysis contain inherent assumptions, and the resultant thermal conductivit...
متن کامل