Parameters of Main Stage of Discharge between Artificial Charged Aerosol Cloud and Ground in Presence of Model Hydrometeor Arrays
نویسندگان
چکیده
Investigation of the discharges from the artificial charged water aerosol clouds in presence of the arrays of the model hydrometeors could help to receive the new data about the peculiarities of the return stroke formation between the thundercloud and the ground when the large volumes of the hail particles participate in the lightning discharge initiation and propagation stimulation. Artificial charged water aerosol clouds of the negative or positive polarity with the potential up to one million volts have been used. Hail has been simulated by the group of the conductive model hydrometeors of the different form. Parameters of the impulse current of the main stage of the discharge between the artificial positively and negatively charged water aerosol clouds and the ground in presence of the model hydrometeors array and of its corresponding electromagnetic radiation have been determined. It was established that the parameters of the array of the model hydrometeors influence on the parameters of the main stage of the discharge between the artificial thundercloud cell and the ground. The maximal values of the main stage current impulse parameters and the electromagnetic radiation registered by the plate antennas have been found for the array of the model hydrometeors of the cylinder revolution form for the negatively charged aerosol cloud and for the array of the hydrometeors of the plate rhombus form for the positively charged aerosol cloud, correspondingly. It was found that parameters of the main stage of the discharge between the artificial charged water aerosol cloud and the ground in presence of the model hydrometeor array of the different considered forms depend on the polarity of the artificial charged aerosol cloud. In average, for all forms of the investigated model hydrometeors arrays, the values of the amplitude and the current rise of the main stage impulse current and the amplitude of the corresponding electromagnetic radiation for the artificial charged aerosol cloud of the positive polarity were in 1.11.9 times higher than for the charged aerosol cloud of the negative polarity. Thus, the received results could indicate to the possible more important role of the big volumes of the large hail arrays in the thundercloud on the parameters of the return stroke for the positive lightning. Keywords—Main stage of discharge, hydrometeor form, lightning parameters, negative and positive artificial charged aerosol cloud. D. S. Zhuravkova, A.G. Temnikov, O.S. Belova, L.L. Chernensky, T.K. Gerastenok, I.Y. Kalugina, N.Y. Lysov, A.V. Orlov are with the Department of Electrophysics and High Voltage Technique, National Research University “Moscow Power Engineering Institute”, Moscow, Russia (corresponding author e-mail: [email protected]). The reported research has fulfilled due to the grant of the Russian Science Foundation (project No. 16-19-00160).
منابع مشابه
Influence of Model Hydrometeor Form on Probability of Discharge Initiation from Artificial Charged Water Aerosol Cloud
Hypothesis of the lightning initiation on the arrays of large hydrometeors are in the consideration. There is no agreement about the form the hydrometeors that could be the best for the lightning initiation from the thundercloud. Artificial charged water aerosol clouds of the positive or negative polarity could help investigate the possible influence of the hydrometeor form on the peculiarities...
متن کاملInvestigation of the Main Stage of a Discharge between an Artificially Charged Water Aerosol Cloud and a Grounded Electrode
Paper presents results of experimental investigation of the main stage of the discharge between an artificially charged water aerosol cloud and a rod on the grounded plate beneath it. Three forms of the main stage of the spark discharge between the charged cloud and grounded electrode have been found. Form I has the weak brightness, the maximal current amplitude not more than 8 A, and the sharp...
متن کاملتاثیر نوع ابرهای پایین جو بر میزان دقت شبیه سازی رواناب در مدل SWAT
Introduction: Patterns of spatial and temporal rainfall impact on runoff and outlet hydrograph (Cordery, 1993; James, 1994). Results of different studies have clarified that simulation by using diverse rainfall data could increase the reliance of results. These were much more sensible in which areas encounter with data scarcity (Mello et al., 2008; Bekiaris et al., 2008). Rainfall properties in...
متن کاملEffects of Plasma Discharge Parameters on the Nano-Particles Formation in the PECVD Reactor
In this paper, the effects of plasma discharge parameters on the nano particles formation process in a plasma enhanced chemical vapor deposition (PECVD) reactor using a model based on equations of ionization kinetics for different active species are studied. A radio frequency applied electric field causes ionization inside the reactor and consequently different reaction schemically active speci...
متن کاملInvestigating the relationship between ground-level particulate matter and aerosol optical depth during dust storm episodes: a case study of Tehran
Background and Objective: During the last few years, air pollution and increasing levels of particulate matters (PMs) have become major public health issues in the megacity of Tehran. The high cost of constructing and maintaining air pollution monitoring stations has made it difficult to achieve adequate spatial-temporal coverage of PM data over various regions. In this regard, the use of remot...
متن کامل