Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions.

نویسندگان

  • Fabien Squara
  • Decebal Gabriel Latcu
  • Youssef Massaad
  • Marouane Mahjoub
  • Sok-Sithikun Bun
  • Nadir Saoudi
چکیده

AIMS During radiofrequency (RF) delivery, lesion volume is highly dependent on contact force (CF). It has recently been shown that changes of bipolar electrogram (EGM) predict transmurality. We hypothesized that there is a correlation between CF and EGM criteria of transmural lesion (TL) during RF. METHODS AND RESULTS We prospectively studied consecutive 512 RF applications from atrial fibrillation ablation procedures. A force-sensing ablation catheter (Tacticath(®), Endosense) was used to continuously measure CF and force-time integral (FTI) during each RF application. Distal bipolar EGM was analysed before, during, and after each RF application. Depending on initial EGM morphology, transmurality of lesions was defined by: (i) disappearance of the positivity after RF when there was QR morphology, (ii) diminution >75% of the positivity when there was QRS morphology, or (iii) disappearance of the R' positivity when there was RSR' morphology. Electrogram criteria were validated by electrophysiologists blinded to force measurements. Force-time integral was higher in TL than in non-transmural lesions (NTLs): 652 ± 248 vs. 212 ± 140 gs (P < 0.001). Mean CF per RF pulse was higher in TL than in NTL: 26.3 ± 12.5 vs. 11.3 ± 10.3 g (P < 0.001). The best cut-off to predict TL was an FTI ≥ 392 gs [sensitivity 0.89, specificity (Sp) 0.93, positive predictive value (PPV) 0.98, and negative predictive value 0.67] and a higher FTI (>700 gs) warrants transmurality of RF atrial lesions (100% Sp and PPV). CONCLUSION Contact force and FTI during RF are correlated with TL. During RF delivery, a target FTI > 392 gs can be used as an endpoint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catheter Contact Force: A Review of Emerging Techniques and Technologies in AF Ablation

Catheter ablation for atrial fibrillation (AF) has gained significant attention during the last decade. Owing to the increase in patients undergoing AF ablation with only moderate long-term outcomes, there is considerable interest in developing new tools to assist the electrophysiologist during the procedure. Catheter contact force (CF) has been known to be an important determinant of radiofreq...

متن کامل

Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain.

BACKGROUND Pulmonary vein reconnection (PVR) still determines recurrences of atrial fibrillation after contact force (CF)-guided pulmonary vein isolation. We studied whether acute PVR (adenosine and waiting time) and late PVR (at repeat) are explained by incomplete transmurality and contiguity within the deployed radiofrequency circle. METHODS AND RESULTS We analyzed 42 CF-guided ipsilateral ...

متن کامل

Contact Force and Atrial Fibrillation Ablation.

Catheters able to measure the force and vector of contact between the catheter tip and myocardium are now available. Pre-clinical work has established that the degree of contact between the radiofrequency ablation catheter and myocardium correlates with the size of the delivered lesion. Excess contact is associated with steam pops and perforation. Catheter contact varies within the left atrium ...

متن کامل

Force‐Sensing Catheters During Pediatric Radiofrequency Ablation: The FEDERATION Study

BACKGROUND Based on data from studies of atrial fibrillation ablations, optimal parameters for the TactiCath (TC; St. Jude Medical, Inc) force-sensing ablation catheter are a contact force of 20 g and a force-time integral of 400 g·s for the creation of transmural lesions. We aimed to evaluate TC in pediatric and congenital heart disease patients undergoing ablation. METHODS AND RESULTS Compr...

متن کامل

Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis.

BACKGROUND In animal studies of radiofrequency ablation, lesion sizes plateau as the maximum lesion size is reached for an ablation. Lesion parameters are not available in clinical ablations, but preclinical work suggests that these correlate with impedance drop and electrogram attenuation. Characterization of the relationships between catheter contact force, ablation duration, and these surrog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2014