Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.
نویسندگان
چکیده
Infusion devices for continuous and precise drug administration are indispensable tools in anaesthesia and critical care medicine. Problems such as start-up delays, non-continuous flow and susceptibility to hydrostatic pressure changes at low infusion rates resulting in accidental bolus release or prolonged flow interruption are inherent to current infusion technology. In order to improve precise drug delivery, an innovative technical concept has been realised in a novel microvolumetric infusion pump (MVIP) device. The MVIP principle includes repeated filling and emptying of a non-compliant microsyringe without the use of valves. The performance of the MVIP prototype has been evaluated and compared with standard syringe infusion pump assemblies. The novel MVIP concept has thereby proven to eliminate most problems during infusion start-up, steady state flow and vertical pump displacement, and has the potential of revolutionising infusion technology and setting a new dimension in patient safety.
منابع مشابه
An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملEfficacy evaluation of syringe pump developed for continuous drug infusion
BACKGROUND In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be recei...
متن کاملStandard drug concentrations and smart-pump technology reduce continuous-medication-infusion errors in pediatric patients.
OBJECTIVE To determine if combining standard drug concentrations with "smart-pump" technology reduces reported medication-infusion errors. DESIGN Preintervention and postintervention comparison of reported medication errors related to infusion therapies during the calendar years 2002 and 2003. SETTING A 242-bed university-affiliated tertiary pediatric hospital. INTERVENTION Change in cont...
متن کاملComputer control of drug delivery by continuous intravenous infusion: bridging the gap between intended and actual drug delivery.
BACKGROUND Intravenous drug infusion driven by syringe pumps may lead to substantial temporal lags in achieving steady-state delivery at target levels when using very low flow rates ("microinfusion"). This study evaluated computer algorithms for reducing temporal lags via coordinated control of drug and carrier flows. METHODS Novel computer control algorithms were developed based on mathemati...