Analysis of thermal therapy using infrared diode lasers operated in continuous wave and pulsed mode
نویسنده
چکیده
The design (software control) guidelines are presented for medical laser systems based on the analysis of the tissue temperature response to various lasers at both cw and pulsed modes. By solving the laser volume-heating diffusion equation, we analyze the roles of various laser and tissue (or water) parameters on the laser-heated solution temperature profiles, including laser intensity, pulse-width, on-off ratio, absorption and thermal constants of the solution or tissues. Two experimental setups are designed to measure the real-time temperature profiles change under laser interactions with results compared to the computer simulations. One experiment uses nano-gold solution which is heated by a diode laser at 808 nm and temperature increases on the surface and inside the solution are monitored for feedback controlled laser on-off time. The other experiment uses water as the solution and heated by a diode laser at 1450 nm. Our new finding includes the optimal control of the laser on-off time and the adjustment of absorption coefficient by off-resonance excitation. The finding and novel features are analyzed theoretically. Correspondence to: Jui-Teng Lin, New Vision Inc., 5F, No. 27, Lane 10, Jiuquan St. Da-tung Dist. Taipei, Taiwan, Tel: 886-961-306-877; E-mail: [email protected]
منابع مشابه
طیف سنج لیزر اختلاف فرکانسMIR برای آشکارسازی CO در شعله
Two continuous-wave (cw) single mode diode-lasers (Toshiba TOLD 9150 and Sharp LT024MDO) are applied as pump and signal sources to obtain difference-frequency generation (DFG) in the mid-infrared (MIR) region by using an AgGaS2 crystal with a length of 30 mm for 90° type I phase-matching. Tuneable MIR laser radiation around 5 µm is obtained with an output power in the order of hundred nW while...
متن کاملComparison of Soft Tissue Thermal Changes Induced by Three Types of Diode Lasers at 810, 940, and 980nm Wavelengths
Background and Aim: Diode laser is a great choice for soft tissue surgery. The diode laser is partially absorbed by hard dental tissues, making it safe for soft tissue surgery. This study aimed to compare the tissue thermal changes induced by three types of diode lasers at 810, 940, and 980nm wavelengths. Materials and Methods: In this in-vitro experimental study, using a diode laser device (c...
متن کاملHistologic evaluation of thermal damage produced on soft tissues by CO2, Er,Cr:YSGG and diode lasers.
OBJECTIVE The aim of this in vitro experimental study was to perform histological evaluation of the thermal effect produced on soft tissue irradiated with CO2, Er,Cr:YSGG or diode lasers. STUDY DESIGN Porcine oral mucosa samples were irradiated with Er,Cr:YSGG laser at 1 W with and without water / air spray, at 2 W with and without water / air spray, and at 4 W with water / air spray, with CO...
متن کاملP 407 Comparison between chorioretinal effects of the continuous versus pulsed-wave by diode-laser in pigmented rabbits
Purpose: To compare the histhologic changes in the retina and chowid, between the continuous and pulsed-wave photocoagulation by diode laser in pigmented rabbits. The r6petitivepulse photocoagulation could prove to be a promising technique for several pathologies in the ocular fundus. Methods: Continuous and pulsed diode-laser transpupillary photocoagulation~ was performed in the eyes of pigmen...
متن کاملP 405 Comparison between chorioretinal effects of the continuous versus pulsed-wave by diode-laser in pigmented rabbits
Purpose: To compare the histhologic changes in the retina and chowid, between the continuous and pulsed-wave photocoagulation by diode laser in pigmented rabbits. The r6petitivepulse photocoagulation could prove to be a promising technique for several pathologies in the ocular fundus. Methods: Continuous and pulsed diode-laser transpupillary photocoagulation~ was performed in the eyes of pigmen...
متن کامل