Occlusive IOLs for intractable diplopia demonstrate a novel near-infrared window of transmission for SLO/OCT imaging and clinical assessment.
نویسندگان
چکیده
PURPOSE Occlusive intraocular lens (IOL) implantation is an effective therapeutic option in patients with intractable diplopia, visual confusion, and unsightly leukocoria. However, their use has been restricted by concerns that inability to visualize the retina may prevent the diagnosis of important posterior pole diseases. In this study, transmission spectra of occlusive IOLs were defined as a basis for acquiring scanning laser ophthalmoscopy/optical coherence tomography (SLO/OCT) images. METHODS Fifteen IOLs of three designs were examined: black small and large PMMA and black Lotus (Morcher GmbH, Stuttgart, Germany). Each IOL was placed between a broad-spectrum white light source and a spectroradiometer, to generate transmission spectra for each lens and determine the cutoff wavelength. Transmission in the near-infrared (NIR) range was confirmed with an 850-nm LED. A model eye was implanted with occlusive IOLs, and SLO/OCT scans were acquired with seven clinical SLO/OCT imaging systems. RESULTS Occlusive IOLs demonstrated high levels of transmission of NIR light. It was determined that most SLO/OCT scanners would achieve 99% to 100% transmission at their operational wavelengths of NIR light. Furthermore, all clinical SLO/OCT imaging systems were capable of imaging fine retinal features without attenuation through occlusive IOLs in a model eye. CONCLUSIONS In this study, a novel NIR window of high-level transmission was identified across the occlusive IOLs with applications to SLO/OCT imaging and NIR-based clinical assessment. The ability to acquire high-quality SLO/OCT scans to detect posterior pole disease may fundamentally change the current view on occlusive IOLs and encourage their use in patients with intractable diplopia.
منابع مشابه
Near-infrared transillumination photography to detect anterior uveal melanomas through black IOLs
Krohn et al describe a novel photographic technique using near-infrared (NIR) transillumination to detect peripheral anterior choroidal and ciliary body melanomas not visible on slit lamp examination. The described imaging technique uses a broad spectrum background light source to illuminate the fundus and external photography with a 720–1100 nm NIR filter to evaluate anterior uveal masses, per...
متن کاملBlack intraocular lenses: near infra-red light transmission may risk treatment failure
Intractable diplopia occurs in approximately 0.8% of patients following strabis-mus surgery, with considerable detriment to visual quality of life. Long-term therapeutic occlusion is required to permit functional vision. Black intraocular lens (IOL) implantation is an effective therapeutic option associated with high rates of postoperative satisfaction. 1 Black IOL implantation entails a cost t...
متن کاملOpaque intraocular lens implantation
Correspondence: CK Patel The Oxford Eye Hospital, West Wing, John Radcliffe Hospital, Headley Way, Headington, Oxford, OX3 9DU, United Kingdom Tel +44 18 6523 4736 Fax +44 18 6524 0097 Email [email protected] We read with great interest the recent article by Lee et al, who described their clinical experience with three patients who underwent primary implantation of Morcher (Stuttgart, Germ...
متن کاملImaging the macula through a black occlusive intraocular lens.
B lack occlusive intraocular lens (IOL) insertion has been shown to be an effective treatment for intractable diplopia, visual confusion, and poor cosmesis resulting from leukokoria. A significant disadvantage of occlusive IOL insertion is that conventional funduscopy is not possible, preventing the detection of posterior pole disease. Here we describe a patient in whom we made the novel discov...
متن کاملAdaptive-optics SLO imaging combined with widefield OCT and SLO enables precise 3D localization of fluorescent cells in the mouse retina.
Adaptive optics scanning laser ophthalmoscopy (AO-SLO) has recently been used to achieve exquisite subcellular resolution imaging of the mouse retina. Wavefront sensing-based AO typically restricts the field of view to a few degrees of visual angle. As a consequence the relationship between AO-SLO data and larger scale retinal structures and cellular patterns can be difficult to assess. The ret...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 6 شماره
صفحات -
تاریخ انتشار 2011