Increasing arterial wall injury after long-term implantation of two types of stent in a porcine coronary model.

نویسندگان

  • S H Hofma
  • D M Whelan
  • H M van Beusekom
  • P D Verdouw
  • W J van der Giessen
چکیده

AIMS There is increased late loss in luminal diameter following long-term coronary stenting, compared with balloon angioplasty. We evaluated short- and long-term vessel wall injury after experimental implantation of two stent designs as well as balloon angioplasty and their relationship to neointimal hyperplasia. METHODS AND RESULTS Wiktor stents and Palmaz-Schatz stents were implanted in normal coronary arteries of pigs (balloon/artery ratio: 0.9-1.1). In control coronary arteries, balloon angioplasty was performed. At 1, 4 and 12 weeks, the vessel injury score, neointimal thickness and inflammatory response were assessed by histology. The vessel injury score increased over time in both Wiktor and Palmaz-Schatz stents: 0.9 +/- 0.1, 1.5 +/- 0.5 and 1.7 +/- 0.6 (mean +/- SD) for Wiktor stents and 0.7 +/- 0.2, 1.0 +/- 0.1 and 1.2 +/- 0.3 for Palmaz-Schatz stents at 1, 4 and 12 weeks follow-up, respectively. No increase in injury was seen in balloon angioplasty controls. Inflammation was seen in both stented groups but was absent 12 weeks after balloon angioplasty. No strong correlation between injury and neointimal thickness was apparent. CONCLUSION Stents induce chronic injury in contrast to balloon angioplasty. Stent design (coil vs slotted tube) as well as inflammation may influence vessel response.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of an Alpha-4 Integrin Inhibitor on Restenosis in a New Porcine Model Combining Endothelial Denudation and Stent Placement

Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where restenosis is assessed after endothelial abrasion of the arterial wall or stent implantation. We combined endothelial cell denudation and implantation of stents to develop a new clinically relevant ...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Acute and Long Term Outcomes of Coronary Intervention in Unprotected Left Main Lesions

Introduction : Significant left main coronary artery stenosis jeopardizes the entire myocardium of the left ventricle and has the worst prognosis of any form of coronary artery disease. Coronary-artery bypass grafting (CABG) has been considered as the standard therapeutic approach for such patients. There are limited data on the safety and effectiveness of percutaneous coronary intervention (PC...

متن کامل

Histopathological Analysis of Drug Eluting Stents in Porcine Coronary Restenosis Model

The aim of this study was to compare the two types of drug-eluting stents with histological analysis in porcine coronary restenosis model. Pigs were randomized into two groups in which the coronary arteries (12 pigs, 12 coronaries in each group) had either biolimus-eluting stent with biodegradable polymer (BPS) or sirolimus-eluting stent with durable polymer (DPS). Radiological analysis was per...

متن کامل

Effect of Pretreatment of Ezetimibe/Simvastatin on Arterial Healing and Endothelialization after Drug-Eluting Stent Implantation in a Porcine Coronary Restenosis Model

BACKGROUND AND OBJECTIVES We sought to evaluate the effect of the early use of ezetimibe/simvastatin (Vytorin®) on arterial healing and endothelialization after the implantation of a drug-eluting stent (DES) in a porcine model of coronary restenosis. MATERIALS AND METHODS A total of 20 pigs (40 coronary arteries) were randomly allocated to a pretreatment or no treatment group. The pretreatmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 1998