Reference values for anterior chamber morphometrics with swept-source optical coherence tomography in a Caucasian population
نویسندگان
چکیده
Purpose The aim of this study is to generate reference values for anterior chamber morphometrics to facilitate the interpretation of anterior chamber images acquired with swept-source optical coherence tomography (SS-OCT) in a Caucasian population. Materials and methods Non-glaucomatous Caucasian subjects, who were newly referred to the outpatient department of the University Eye Clinic Maastricht UMC+, were asked to undergo anterior segment assessment with SS-OCT imaging prior to routine eye examination (including visual acuity and refractive error measurements, Goldmann applanation tonometry, slit lamp examination and funduscopy). Results A total of 647 Caucasian subjects, aged 40-80 years, were included. Mean age (± standard deviation) was 61.7±10.3 years, and 294 were male (45%). Mean refractive error was -0.63±3.17 D. OCT images and measurements were obtained in all cases. The mean temporal trabecular iris angle at 500 µm (TIA500) was 27.04°±12.04°, the mean nasal TIA500 was 27.43°±11.75°, the mean anterior chamber depth (ACD) was 2.75±0.39 mm and the mean lens vault (LV) was 0.44±0.30 mm. A smaller temporal TIA500, shallower ACD and higher LV were found in female and hyperopic subjects. Conclusion Reference values for anterior chamber morphometrics in Caucasians were generated, quantified and presented. These values offer tools for the interpretation of anterior segment images of Caucasians and differentiation between presumed mechanisms of angle closure.
منابع مشابه
Reproducibility of anterior chamber angle analyses with the swept-source optical coherence tomography in young, healthy Caucasians.
PURPOSE To assess the reproducibility of iridocorneal angle (ICA) analysis in young, healthy Caucasian subjects using swept-source optical coherence tomography (SS-OCT) by determining variability and interobserver agreement between expert and nonexpert observers. METHODS Thirty-one healthy volunteers (nonexperts) acquired three consecutive SS-OCT images of the right eyes of their peer nonexpe...
متن کاملAssessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery
Purpose. To compare the changes of anterior segment parameters, assessed by swept source anterior segment optical coherence tomography (AS-OCT) after combined Trabectome-cataract surgery and Trabectome-only surgery in open angle glaucoma patients. Methods. Thirty-eight eyes of 24 patients with open angle glaucoma were scanned with swept source AS-OCT before and 4 weeks after combined Trabectome...
متن کاملChanges in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
The aim of this study was to investigate changes in the anterior segment of the eye after cycloplegia. A biometer combined with swept-source optical coherence tomography (SSOCT) was used for measurements. Patients with strabismus or amblyopia who underwent cycloplegia were included. The axial length, central corneal thickness, anterior chamber depth, and lens thickness were measured with the bi...
متن کاملAnterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement.
PURPOSE To evaluate the reproducibility of anterior chamber angle measurements obtained by swept-source optical coherence tomography (OCT) and to identify factors associated with its measurement variability. METHODS One eye from each of 30 healthy subjects was randomly selected for anterior segment OCT imaging (Casia SS-1000 OCT; Tomey, Nagoya, Japan) in three separate visits within a week. T...
متن کاملAgreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
Purpose To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). Methods Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty-degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and...
متن کامل