A candidate reference method for coupled sodium-water determination in human serum.

نویسندگان

  • J D van Suijlen
  • C A Berrevoets
  • B Leijnse
چکیده

A candidate reference method is described for coupled sodium-water determination based on ion-exchange sodium separation from the serum matrix followed by gravimetry as Na2SO4, and serum water determination by means of microwave evaporation. For sera with normal sodium and water contents, the mean relative standard deviation is 0.6% (0.8 mmol/l). Mean inaccuracy for the coupled sodium-water determination is -0.3% (0.4 mmol/l). The candidate reference method can be considered a reference method because the reference method value did not differ significantly from the definitive value, there is no known source for interferences or bias, and misinterpretation due to abnormal protein or lipid levels is excluded because serum sodium is determined on a plasma water basis. Sodium concentrations determined by the candidate reference method are used for comparing field methods with the candidate reference method. If the resulting regression equation is used in the calibration procedure, good correlation between all (in)direct field methods and the candidate reference method is ensured, and accurate results are produced. Results of proficiency testing show a good correlation between (in)direct field methods and the candidate reference method, because sera with approximately normal water contents are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه روش‌های پروتئین‌زدایی در سنجش نیتریک اکساید سرمی به روش گریس

Background: Nitric oxide (NO) is involved in numerous physiologic and phathophysiologic processes. Recently, further investigators have focused on serum NO determination. In our previous study, we validated a simple, cheap and rapid method for serum NO determination based on the Greiss reaction. Deproteinization is a necessary step for this reaction, thus, the present study was designed to asse...

متن کامل

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

Determination of sodium in blood serum by inductively coupled plasma mass spectrometry

Owing to its importance as a serum electrolyte, sodium is determined routinely in clinical laboratories. In the United States, the accuracy of these measurements is assessed through a number of proficiency testing programs. Clinical measurements are supported by the National Institute of Standards and Technology through the production of serum matrix Standard Reference Materials (909 and 956 se...

متن کامل

روشی سریع و آسان برای اندازه‌گیری اسپکتروفتومتری دی ‌متیل‌آمینو‌اتیل آزید (DMAZ) (علمی-پژوهشی)

Dimethylaminoethyl azide (DMAZ) is a good candidate fuel for hydrazine derivatives in aerospace industries. DMAZ is synthesized via reaction of dimethyl aminoethyl hydrochloride with sodium azide in aqueous solution, which, in next step, by adding of concentrated sodium hydroxide, organic phase is separated. Therefore, the determination of amount of unextracted DMAZ in aqueous phase (wastewater...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 28 11  شماره 

صفحات  -

تاریخ انتشار 1990