Aliasing effects in digital images of line-pair phantoms.

نویسندگان

  • Michael Albert
  • Daniel J Beideck
  • Predrag R Bakic
  • Andrew D A Maidment
چکیده

Line-pair phantoms are commonly used for evaluating screen-film systems. When imaged digitally, aliasing effects give rise to additional periodic patterns. This paper examines one such effect that medical physicists are likely to encounter, and which can be used as an indicator of super-resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

رفع اعوجاج هندسی متون به‌کمک اطلاعات هندسی خطوط متن

Document images produced by scanners or digital cameras usually have photometric and geometric distortions. If either of these effects distorts document, recognition of words from such a document image using OCR is subject to errors. In this paper we propose a novel approach to significantly remove geometric distortion from document images. In this method first we extract document lines from do...

متن کامل

Optimization of Digital Mammography Resolution Using Magnification Technique in Computed Radiography

Purpose: To determine whether magnified digital mammography using a computed radiography system can produce better spatial resolution by reducing the focus-object distance, and to define the optimal magnification factor when a large x-ray tube focal spot is used for digital mammography using a CR system. Materials and Methods: Digital images obtained using computed radiography of a breast phant...

متن کامل

Temperature Mapping Using Ultrasound Digital Images

Introduction:  The  success  of  hyperthermia  depends  on  the  accuracy  of  the  temperature  monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes  were determined by computing the speckle displacement in the ultrasound digital images. Speckle  tracking algorithm was used to compute the displacement.  Materials and Methods: The experiment was perf...

متن کامل

A Proposed Simple Teleradiology System Using a Digital Camera

Background & Aims: Teleradiology as an efficient way for avoiding unnecessary transfer of patients to special medical centers requires the images with digital format. However, in some developing countries, including Iran, imaging is being done using non digital devices. In such cases, changing analog images into digital ones can solve the problem. The method which is nowadays used for digita...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 29 8  شماره 

صفحات  -

تاریخ انتشار 2002