Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant

نویسندگان

  • Urban Hedlundh
  • Lars Karlsson
چکیده

Distally anchored uncemented modular tapered porous stems are often the preferred treatment in total hip arthroplasty revisions and failed subtrochanteric fractures. These conditions mainly affect elderly osteoporotic patients, with an increased risk of later fractures below the well-fixated implant. Treatment in secondary fractures with long looking plates is the recommended treatment, where stability is a key to fracture healing. We report a complicated case in which this was achieved by an innovative technique combing the trochanteric attachment bolt of the stem system and a locking plate with polyaxial screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report

INTRODUCTION The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain rad...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation.

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...

متن کامل

Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis

BACKGROUND AND PURPOSE Historically, the treatment of periprosthetic femoral fractures (PFFs) has been associated with a high frequency of complications and reoperations. The preferred treatment is internal fixation, a revision of the femoral stem, or a combination of both. An improved understanding of plate use during internal fixation, and the introduction of locking-plate osteosynthesis may ...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016