[Value of serum PSA and PAP measurement with newly developed latex turbidimetric immunoassay].

نویسندگان

  • H Akino
  • H Tsuka
  • K Okada
  • Y Tsuchiya
  • M Matsubara
  • K Arimura
چکیده

Serum prostate specific antigen (PSA) and prostatic acid-phosphatase (PAP) levels in normal controls, and patients with prostate cancer, benign prostate hypertrophy (BPH) and other urological diseases were examined with a newly developed latex turbidimetric immunoassay (LPIA ACE PSA, LPIA ACE PAP, IATRON LABORATORIES, INC., Tokyo, Japan). The advantageous characteristics of this method are small amount (10 microliters) of serum required and short time (about 20 min.) for performing this assay. There was a high linear correlation between LPIA ACE PSA and MARKIT-F PA (r2 = 0.953), between LPIA ACE PSA and TANDEM-E PSA (r2 = 0.881) and between LPIA ACE PAP and ABBOTT-PAP EIA (r2 = 0.946). When the BPH patients (n = 110) were used as negative controls, the cut-off value of PSA was determined to be 4.3 ng/ml. Using this level as the cut-off value, the sensitivity was 78% (42 positive/54 untreated prostate cancer patients), specificity (negative rate in BPH patients) was 95% and efficiency was 89%. In a follow-up study of prostate cancer, the PSA value was elevated above the cut-off value in 68% at the time of clinical progression. These findings suggest that LPIA ACE PSA is a useful tool for serum PSA measurement. The cut-off value of PAP measured with LPIA ACE PAP was 9.0 ng/ml, which was determined by the same method as PSA. The sensitivity, specificity and efficiency ware 39%, 96% and 77%, respectively. These findings indicate that PAP is less useful than PSA in the diagnosis of prostate cancer.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stabilization of turbidimetric immunoassay by covalent coupling of antibody to latex particles.

Turbidimetric immunoassay is commonly used to quantify serum proteins. Latex-particle enhancement of this type of assay has been primarily associated with increasing assay sensitivity. However, covalent coupling of an antibody to a latex particle can offer other advantages that are also pertinent in measurement of high concentrations of analytes. By using a common antibody with IgG as a model a...

متن کامل

Use of microtiter plates for latex agglutination immunoassay of serum alpha 2-macroglobulin.

A simple, sensitive turbidimetric immunoassay is described for analysis of alpha 2-macroglobulin (AMG) in serum, using microtiter plates and a commercial kit that features a sensitive latex reagent. Using microwells as reaction vessels and the latex reagent made it possible to minimize the sample size and the amounts of reagents. The procedure involves two pipetting steps and a brief incubation...

متن کامل

Serum cystatin C measured by automated immunoassay: a more sensitive marker of changes in GFR than serum creatinine.

Serum cystatin C has been suggested as a new marker of GFR. For the introduction of this marker into clinical use a rapid and automated method is required. We have developed and validated an assay for serum cystatin C using latex particle-enhanced immunoturbidimetry. Intra- and inter-assay precision were < 3% and < 5% across the assay range. Analytical recovery was 93 +/- 3.8% and no lack of pa...

متن کامل

Particle-enhanced turbidimetric immunoassay of sex-hormone-binding globulin in serum.

A particle-enhanced turbidimetric immunoassay (PETIA) for human sex-hormone-binding globulin (SHBG) is described. The method involves use of antibody covalently coupled to latex particles and is almost fully automated, with sample processing being complete in less than 20 min. The working reagents are stable for at least three months, and full calibration of the assay each day is not essential....

متن کامل

Preliminary evaluation of the performance of a new, highly sensitive commercial immunoassay for serum ferritin determination.

We evaluated the analytical performance of a new, commercial, fully automated immunoturbidimetric assay for the determination of ferritin [FER-Latex(X2)CN SEIKEN, Denka Seiken, Japan] in serum on the Olympus AU2700 analyzer. The new assay is a latex-enhanced turbidimetric immunoassay with an analysis time of 10 min. The linearity of the assay was confirmed up to 2505 pmol/L (R2=0.999). The dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hinyokika kiyo. Acta urologica Japonica

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 1995