Door Opening Affects Operating Room Pressure During Joint Arthroplasty.
نویسندگان
چکیده
Many resources are expended to ensure a sterile operating room environment. Efforts are made to prevent exposure of patients to personnel and to achieve positive room pressure to keep out airborne contaminants. Foot traffic into and out of the operating room during surgery can undermine these efforts. The authors investigated the number and duration of operating room door openings during hip and knee arthroplasty procedures and the effect of the door openings on room pressure. They tested the hypothesis that door openings defeat positive pressure, permitting air flow into the room. Room pressure and door status were monitored electronically during 191 hip and knee arthroplasty procedures. Operating room staff were unaware that data were being collected. The authors evaluated the data with regression analysis to determine whether the number and duration of door openings had an effect on room pressure. Significance was set at P<.05. Doors were open, on average, 9.5 minutes per case. In 77 of 191 cases, positive pressure was defeated, allowing air flow to reverse into the operating room. Total time with the door open significantly affected the minimum pressure recorded in the room (P<.02), but did not significantly affect average room pressure (P=.7). This finding suggested that the loss of positive pressure was a transient event from which the room recovered. The number and duration of door openings showed a significant association with length of surgery. Door openings threaten positive pressure, potentially jeopardizing operating room sterility. The causes of excessive operating room traffic must be evaluated to identify ways to reduce this traffic and the associated risks.
منابع مشابه
The Prevention of Periprosthetic Joint Infections
Periprosthetic joint infection (PJI) following total joint arthroplasty (TJA) adversely affects patient quality of life and health status, and places a huge financial burden on the health care. The first step in combating this complication is prevention, which may include implementation of strategies during the preoperative, intraoperative, or postoperative period. Optimization of the patient w...
متن کاملCost Effectiveness of Laminar Flow Systems for Total Shoulder Arthroplasty: Filtering Money from the OR?
Background: Laminar flow ventilation systems were developed to reduce surgical contamination in joint arthroplastyto avoid periprosthetic joint infection (PJI). The goals of this study are to evaluate the cost-effectiveness and economicviability of installing and maintaining a laminar flow system in an operating room.Methods: A Monte Carlo simulation was used to evaluate the c...
متن کاملOperating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.
BACKGROUND Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. AIM To evaluate air...
متن کاملDoor to relocation time for dislocated hip prosthesis: multicentre comparison of emergency department procedural sedation versus theatre-based general anaesthesia.
BACKGROUND Dislocation of a hip prosthesis is a painful event which has an incidence of 4% for primary total hip arthroplasty. Relocation is traditionally performed under general anaesthesia in the operating theatre, but relocation using sedation in the emergency department (ED) has been reported, with a limited success rate of 62%. A study was undertaken to compare door to relocation times for...
متن کاملCurrent Evidence for the Use of Laminar Flow in Reducing Infection Rates in Total Joint Arthroplasty.
Since the introduction of laminar air flow in orthopaedic theatres by Sir John Charnley, it has widely become accepted as the standard during orthopaedic procedures such as joint arthroplasty. We present a review of available current literature for the use of laminar flow operating theatre ventilation during total joint arthroplasty and examines the effectiveness of laminar flow ventilated oper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 39 2 شماره
صفحات -
تاریخ انتشار 2015