Postoperative Life-Threatening Recurrent Ventricular Arrhythmia Triggered by the Swan-Ganz Catheter in a Patient Undergoing Off-Pump Coronary Artery Bypass Surgery
نویسندگان
چکیده
Recurrent ventricular arrhythmia can be fatal and cause serious complications, particularly when it is caused immediately after an operation. Incorrect placement of a Swan-Ganz catheter can trigger life-threatening ventricular arrhythmia, but even intensive care specialists tend to miss this fact. Here, we report a case of recurrent ventricular arrhythmia causing a severe hemodynamic compromise; the arrhythmia was induced by a severely angulated Swan-Ganz catheter. The recurrent ventricular arrhythmia was not controlled by any measures including repositioning of the catheter, until the complete removal of the Swan-Ganz catheter. It is necessary to keep in mind that the position of the pulmonary artery catheter should be promptly checked if there is intractable recurrent ventricular arrhythmia.
منابع مشابه
On-Pump Beating Coronary Artery Bypass in High Risk Coronary Patients
Background: There are some conflicting results with Conventional Coronary Artery Bypass Grafts (CCABG) with arrested heart in coronary high-risk patients. Moreover, performing off-pump CABG in these cases may be associated with serious complications. The objective of this study is to evaluate the efficacy of the on-pump beating CABG (OPBCABG) in coronary high-risk patients in comparison with th...
متن کاملManagement of Catheter Induced Upper Limb Suppurative Thrombophlebitis in a Patient after Coronary Artery Bypass Graft Surgery: a Case Report
Introduction: One of the important complications of peripheral venous catheters is suppurative thrombophlebitis that would be life threatening without treatment. In this report, we introduce a patient who developed purulent thrombophlebitis due to venous catheter in the upper limb after coronary artery bypass graft surgery. Multiple abscess formation was developed on her upper limb after the th...
متن کاملUse of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملComparison of Treatment Outcomes in Off-pump Coronary Artery Bypass Graft and Medical Therapy in Patients with Triple-vessel Coronary Artery Disease and Severe Ventricular Dysfunction
Introduction: Heart failure is a major hazard for public health. Despite recent advance in medical therapy, there is not enough information on the outcome of off-pump coronary artery bypass (OPCAB) and medical therapy on the patients with severe ventricular dysfunction and triple-vessel (CAD). This study aimed to compare treatment outcomes and mortality rate in patients undergoing off-pump coro...
متن کاملChange in right ventricular function during off-pump coronary artery bypass graft surgery.
OBJECTIVES Hemodynamic derangement during displacement of beating heart in off-pump coronary artery bypass graft (OPCAB) surgery might be related with right ventricular (RV) dysfunction. We evaluated RV function and hemodynamic alterations using a thermodilution pulmonary artery catheter. METHODS The study included 30 patients undergoing OPCAB, using single pericardial suture and tissue stabi...