An ultra-high-speed Scheimpflug camera for evaluation of corneal deformation response and its impact on IOP measurement.
نویسندگان
چکیده
PURPOSE To investigate the test-retest variability of and factors associated with the corneal deformation response, and evaluate its impact on IOP measurement. METHODS Forty normal and 140 glaucoma suspect/glaucomatous eyes of 104 individuals were prospectively included for repeated measurements of corneal deformation response by an ultra-high-speed Scheimpflug camera, followed by corneal hysteresis and corneal resistance factor measurements by the ocular response analyzer, and dynamic contour tonometry (DCT) (the reference standard) and Goldmann applanation tonometry (GAT) during the same visit. The test-retest variability of corneal deformation response was evaluated. Univariate and multivariate linear mixed models were used to identify factors (age, manifest spherical refractive error, axial length, IOP, central corneal thickness [CCT], corneal curvature, corneal hysteresis, and corneal resistance factor) associated with corneal deformation response and the difference between DCT and GAT measurements. RESULTS Corneal deformation amplitude (CDA) had an intraclass correlation coefficient of 0.86. There was no difference in CDA between the glaucoma and nonglaucoma groups. A higher IOP, a younger age, and a greater CCT were associated with a smaller CDA (P ≤ 0.002) (n = 180). In the univariate analysis (n = 180), the difference between DCT and GAT measurements was associated with spherical refractive error (P = 0.037), CCT (P = 0.004), and CDA (P < 0.001) after adjusting the effect of IOP (DCT). In the multivariate analysis, the only factor associated with the IOP difference was CDA (P = 0.003). CONCLUSIONS CDA was a reliable indicator to quantify corneal deformation response. CDA, rather than CCT, was the key source of measurement error of GAT.
منابع مشابه
Impact of chamber pressure and material properties on the deformation response of corneal models measured by dynamic ultra-high-speed Scheimpflug imaging.
PURPOSE To study the deformation response of three distinct contact lenses with known structures, which served as corneal models, under different chamber pressures using ultra-high-speed (UHS) Scheimpflug imaging. METHODS Three hydrophilic contact lenses were mounted on a sealed water chamber with precisely adjustable pressure: TAN-G5X (41% hydroxyethylmethacrylate/glycolmethacrylate, 550 µm ...
متن کاملEffects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera.
PURPOSE To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. METHODS Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy ey...
متن کاملComparison of three intraocular pressure measurement methods including biomechanical properties of the cornea.
PURPOSE The aim of this study was to show the usefulness of three methods for measuring IOP: Goldmann applanation tonometry, rebound tonometry, and Ultra-High-Speed Scheimpflug technology. METHODS The examined group consisted of 96 patients (192 eyes), including 63 women and 33 men with a mean age of 59.3 ± 19.9 years. Together, 152 healthy eyes and 40 eyes with different pathologies were exa...
متن کاملFactors Associated With Corneal Deformation Responses Measured With a Dynamic Scheimpflug Analyzer.
Purpose The purpose of this study was to clarify correlations between corneal deformation parameters measured with a dynamic Scheimpflug analyzer and baseline factors such as axial length, intraocular pressure (IOP), age, central corneal thickness (CCT), and corneal curvature. Methods Ninety-six eyes of 96 healthy subjects (mean 55.2 ± 16.1 years of age) were examined using a dynamic Scheimpf...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 54 4 شماره
صفحات -
تاریخ انتشار 2013