Contrast Response Functions for Single Gabor Patches: ROI-Based Analysis Over-Represents Low-Contrast Patches for GE BOLD

نویسندگان

  • Jennifer F. Schumacher
  • Serena K. Thompson
  • Cheryl A. Olman
چکیده

IMPORTANT FOR THE INTERPRETATION OF BOLD FMRI DATA IS A LINEAR RELATIONSHIP BETWEEN THE BOLD RESPONSE AND THE UNDERLYING NEURAL ACTIVITY: increased BOLD responses should reflect proportionate increases in the underlying neural activity. While previous studies have demonstrated a linear relationship between the peak amplitude of the BOLD response and neural activity in primary visual cortex (V1), these studies have used stimuli that excite large areas of cortex, and the linearity of the BOLD response has not been demonstrated when only a small patch of cortex is stimulated. The BOLD response to isolated Gabor patches of increasing contrast was measured with gradient echo (GE) BOLD and spin echo (SE) BOLD at 7 T. Our primary finding is notable spatial heterogeneity of the BOLD contrast response, particularly for the GE BOLD data, resulting in a more reliably linear relationship between BOLD data and estimated neural responses in the center of the cortical representations of the individual Gabor patches than near the edges. A control experiment with larger sinusoidal grating patches confirms that the observed sensitivity to voxel selection in the regions of interest-based analysis is unique to the small stimuli.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution BOLD fMRI measurements of local orientation-dependent contextual modulation show a mismatch between predicted V1 output and local BOLD response

The blood oxygenation level-dependent (BOLD) functional MRI response to suppressive neural activity has not been tested on a fine spatial scale. Using Gabor patches placed in the near periphery, we precisely localized individual regions of interest in primary visual cortex and measured the response at a range of contrasts in two different contexts: with parallel and with orthogonal flanking Gab...

متن کامل

Comparison of the location and extent of BOLD activation in high spatial resolution SE and GE fMRI of the Motor Cortex at 7T

Introduction: fMRI studies generally employ gradient-echo (GE) BOLD contrast due to the limited signal change and signal-to-noise ratio (SNR) of spin echo (SE) BOLD contrast at standard field strength. Ultra-high field (7T) provides increased BOLD contrast-to-noise ratio (CNR) and decreases the contribution that large vessels make to GE BOLD contrast, due to higher capillary contribution and th...

متن کامل

کنترل فعال ارتعاشات موضعی یک ورق مستطیلی با وصله­های پیزوالکتریک

 Active control vibrations of an arbitrary point of a simply supported rectangular plate is presented in this paper. The governing differential equation of plate with attached piezoelectric sensor/actuator patches, whose effects of mass and stiffness are included by the local functions, is solved at first. The response of the plate is computed using the first nine natural modes. Then, piezoelec...

متن کامل

Contrast sensitivity for letter optotypes vs. gratings under conditions biased toward parvocellular and magnocellular pathways

This study examined the extent to which letter optotypes and grating stimuli provide equivalent measures of contrast sensitivity under conditions designed to favor the magnocellular (MC) and parvocellular (PC) pathways. The contrast sensitivity functions (CSFs) of three visually normal observers were measured for Sloan letters and Gabor patches, using steady- and pulsed-pedestal paradigms to bi...

متن کامل

Double-Gabor Filters Are Independent Components of Small Translation-Invariant Image Patches

The analysis of natural images with independent component analysis (ICA) yields localized bandpass Gabor-type filters similar to receptive fields of simple cells in visual cortex. We applied ICA on a subset of patches called position-centered patches, selected for forming a translation-invariant representation of small patches. The resulting filters were qualitatively different in two respects....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011