Laboratory assessment of oxygenation in methemoglobinemia.

نویسندگان

  • Shannon Haymond
  • Rohit Cariappa
  • Charles S Eby
  • Mitchell G Scott
چکیده

BACKGROUND This case conference reviews laboratory methods for assessing oxygenation status: arterial blood gases, pulse oximetry, and CO-oximetry. Caveats of these measurements are discussed in the context of two methemoglobinemia cases. CASES Case 1 is a woman who presented with increased shortness of breath, productive cough, chest pain, nausea, fever, and cyanosis. CO-oximetry indicated a carboxyhemoglobin (COHb) fraction of 24.9%. She was unresponsive to O(2) therapy, and no source of carbon monoxide could be noted. Case 2 is a man who presented with syncope, chest tightness, and signs of cyanosis. His arterial blood was dark brown, and CO-oximetry showed a methemoglobin (MetHb) fraction of 23%. ISSUES Oxygen saturation (So(2)) can be measured by three approaches that are often used interchangeably, although the measured systems are quite different. Pulse oximetry is a noninvasive, spectrophotometric method to determine arterial oxygen saturation (S(a)O(2)). CO-oximetry is a more complex and reliable method that measures the concentration of hemoglobin derivatives in the blood from which various quantities such as hemoglobin derivative fractions, total hemoglobin, and saturation are calculated. Blood gas instruments calculate the estimated O(2) saturation from empirical equations using pH and Po(2) values. In most patients, the results from these methods will be virtually identical, but in cases of increased dyshemoglobin fractions, including methemoglobinemia, it is crucial that the distinctions and limitations of these methods be understood. CONCLUSIONS So(2) calculated from pH and Po(2) should be interpreted with caution as the algorithms used assume normal O(2) affinity, normal 2,3-diphosphoglycerate concentrations, and no dyshemoglobins or hemoglobinopathies. CO-oximeter reports should include the dyshemoglobin fractions in addition to the oxyhemoglobin fraction. In cases of increased MetHb fraction, pulse oximeter values trend toward 85%, underestimating the actual oxygen saturation. Hemoglobin M variants may yield normal MetHb and increased COHb or sulfhemoglobin fractions measured by CO-oximetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An unusual electrophoresis.

1. Percy MJ, Lappin TR. Recessive congenital methaemoglobinaemia: cytochrome b(5) reductase deficiency. Br J Haematol 2008;141:298–308. 2. Pallais JC, Mackool BT, Bishop Pitman M. Case 7-2011: a 52-year-old man with upper respiratory symptoms and low oxygen saturation levels. N Engl J Med 2011;364:957–66. 3. Haymond S, Cariappa R, Eby CS, Scott MG. Laboratory assessment of oxygenation in methem...

متن کامل

WARNINGS AND PRECAUTIONS 5.1 Rebound Pulmonary Hypertension Syndrome following Abrupt Discontinuation 5.2 Hypoxemia from Methemoglobinemia 5.3 Airway Injury from Nitrogen Dioxide

INDICATIONS AND USAGE INOmax is a vasodilator, which, in conjunction with ventilatory support and other appropriate agents, is indicated for the treatment of term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension, where it improves oxygenation and reduces the need for extracorporeal memb...

متن کامل

Suspected methemoglobinemia following awake intubation: one possible effect of benzocaine topical anesthesia--a case report.

Methemoglobinemia is a potential negative side effect associated with the use of benzocaine for topical anesthesia. A healthy patient admitted for an outpatient orthopedic procedure developed the clinical symptomatology of methemoglobinemia after topicalization of the airway with benzocaine. The patient subsequently responded to appropriate treatment and was fit for discharge the same day. Meth...

متن کامل

Congenital Methemoglobinemia

Congenital methemoglobinemia is a rare cause of cyanosis. We report a case of a girl, 17 years old with peripheral cyanosis and normal cardio-pulmonary system. She was diagnosed as a case of methemoglobinemia based on findings of polycythemia and HbM band on hemoglobin electrophoresis. We emphasize the importance of this rare entity in the differential diagnosis of cyanosis.

متن کامل

P-Chloroaniline Poisoning Causing Methemoglobinemia: A Case Report and Review of the Literature

Background. Methemoglobin (MetHb) most commonly results from exposure to an oxidizing chemical but may also arise from genetic, dietary, or even idiopathic etiologies. P-chloroaniline (PCA) was one of the first substances described in the context of acquired methemoglobinemia. Case Report. We report the case of a cyanotic chemistry worker who presented to our emergency department (ED) after wor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2005