Thrombogenicity of sirolimus-eluting stents and bare metal stents: evaluation in the early phase after stent implantation.

نویسندگان

  • Thomas Walter
  • Katja S Rey
  • Hans Peter Wendel
  • Sebastian Szabo
  • Tim Suselbeck
  • Carl-Erik Dempfle
  • Martin Borggrefe
  • Stefanie Swoboda
  • Martin E Beyer
  • Hans Martin Hoffmeister
چکیده

BACKGROUND Thrombogenicitiy of drug-eluting stents is a matter of controversial debate. The aim of this study was to evaluate the thrombogenicity of sirolimus-eluting stents (SES) compared to bare metal stents (BMS) in a standardised in vitro model. MATERIALS AND METHODS Nine SES and nine BMS were implanted in tubing loops and nine loops without stent served as controls. Initially and after 90 minutes of blood circulation in a modified chandler loop model, thrombin-antithrombin III complex (TAT), PMN-elastase, factor XIIa, SC5b-9, sP-selectin and platelet count were measured. Expression of CD62P, CD45/41 and PAC-1 on platelets were determined by flow cytometry. RESULTS After 90 minutes, platelet count decreased significantly in the loops with BMS and SES (p<0.05). Levels of TAT, PMN-elastase and SC5b-9 were significantly elevated after 90 minutes in all loops (p<0.05). sP-selectin significantly increased in the loops with BMS and SES after 90 minutes. No significant changes occurred in any flow cytometric data. Platelet count, sP-selectin, TAT, PMN-elastase, SC5b-9, CD62P, CD41/CD45 and PAC-1 showed no significant difference between BMS and SES. CONCLUSION These data provide evidence that there is no difference in thrombogenicity of BMS and SES in the in vitro model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) substudy.

BACKGROUND Randomized clinical trials have shown that a sirolimus-eluting stent significantly reduces restenosis after percutaneous coronary revascularization. Diabetic patients are known to have a higher risk of restenosis compared with nondiabetic patients. The purpose of this analysis was to determine the impact of sirolimus-eluting stents on outcomes of diabetic compared with nondiabetic pa...

متن کامل

The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

BACKGROUND Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. METHODS Sirolimus-eluting stents were implanted in 88 lesions a...

متن کامل

Evaluation of the haemodynamic characteristics of drug-eluting stents at implantation and at follow-up.

AIMS The aim of this study was to investigate the physiologic parameters: fractional flow reserve (FFR), hyperaemic trans-stent gradient (HTG), and wall shear stress (WSS) at implantation and at 6-month follow-up in the drug-eluting sirolimus stent and in its bare metal counterpart implanted in pairs within the same patient. METHODS AND RESULTS Twenty patients, accepted for percutaneous coron...

متن کامل

Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents

BACKGROUND Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal mo...

متن کامل

[Comparative analysis of intimal hyperplasia after sirolimus-eluting stent and thin-strut bare-metal stent implantation in small coronary arteries].

OBJECTIVE This study aimed at evaluating reduction in intimal hyperplasia volume following angioplasty using sirolimus-eluting stents (Cypher) compared with thin-strut bare-metal stents (Pixel) in patients with small vessels. METHODS Eighty patients with coronary artery disease were prospectively included in two consecutive series, the first using sirolimus-eluting stents (50) and the second ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • In vivo

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 2010